Küppersbusch KD 674.1GE Instructions For Use And Installation Instructions Download Page 4

17

Part 1 - INSTALLATION INSTRUCTIONS

3.8 - Before carring out any kind of maintenance or cleaning, disconnect the hood from the

mains  supply.

3.9  - If the room where the cooker hood is to be used contains a fuel burning appliance such

as a central heating boiler then this must be of the room sealed or balanced flue type.
If other types of flue or appliance are fitted ensure that there is an adequate supply of
air into the room. When the cooker hood is used in conjunction with other appliances
supplied  with  energy  other  than  electric,  the  negative  pressure  in  the  room  must  not
exceed  0,04  mbar  to  prevent  fumes  being  drawn  back  into  the  room  by  the  cooker
hood.

4  -  INSTALLATION

The versatility of the ducting fan unit on this hood enables it to be installed in one of
four different ways:

1 - Air outlet directed upwards (ducting or recirculation fitting).
2 - Air outlet directed towards the wall (ducting fitting only).
3 - Air outlet directed to the right or left (ducting fitting only). For correct installation of

the hood, please proceed in the following stages:

4.1 - Selection of the type of installation
4.2 - Installation of the hood canopy C
4.3 - Installation of the chimney A
4.4 - Ducting or recirculation fitting
4.5 - Electrical connection and testing

4.1  -  Selecting  the  type  of  installation

1 - Air discharge towards the top

In this case the hood can be used
either in filter mode (

fig. 2a

) or in

suction mode (

fig. 2b

).

2 - Air  discharge  towards  the  wall

(fig. 3)

In this case the hood can only be
used in suction mode.

3 - Side air discharge, Lh or Rh (fig.

4a-b).

In this case the hood can only be
used in suction mode.

G

2a

2b

S07_02

2

2

4

4

3

3

Summary of Contents for KD 674.1GE

Page 1: ...ageanweisungen Instructions for use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje KD 674 1GE KD 974 1GE ...

Page 2: ...ENZIONE 13 3 1 Filtri antigrasso metallici 14 3 2 Filtro al carbone attivo 14 3 3 Illuminazione 15 3 4 Pulizia 15 1 GENERAL DATA 16 2 COMPONENTS 16 3 SAFETY WARNINGS 16 4 INSTALLATION 17 4 1 Selecting the type of installation 17 4 2 Installation of the hood canopy C 18 4 3 Installation of the chimney A 20 4 4 Ducting or recirculation fitting 22 4 5 Connection to power supply and checking of good w...

Page 3: ...g spigot R 2 6 No 1 support rod B 2 7 No 1 fixing kit containing No 1 wall bracket S to fix the canopy hood No 1 cover D screws rawl plugs and documentation 3 SAFETY WARNINGS 3 1 When used in the extraction mode the cooker hood ducting must not be connected to a flue which is used for exhausting fumes from appliances supplied with energy other than electric such as a central heating flue or water ...

Page 4: ...fan unit on this hood enables it to be installed in one of four different ways 1 Air outlet directed upwards ducting or recirculation fitting 2 Air outlet directed towards the wall ducting fitting only 3 Air outlet directed to the right or left ducting fitting only For correct installation of the hood please proceed in the following stages 4 1 Selection of the type of installation 4 2 Installation...

Page 5: ...on Z of the chimney required for installation plus 11 mm X Z 18 7 Using a Ø8 mm drill bit drill the points marked in this way b When installed with the air outlet directed towards the wall fig 5a it will be necessary to drill an air ducting opening measuring Ø120 or 150 mm according to the diameter of the flange F provided 2 Fitting the fixing elements a Insert the rawl plugs provided into holes 1...

Page 6: ...ig 9 d Adjust the support rod B so that it pushes against the wall fig 10 e Adjusting position fig 11 There are two adjustable hooks at the rear of the hood which can be used to adjust its position as follows Turn the screws L until the position of screws N coincides with the lower access holes Turn the screws N to adjust the vertical and horizontal position of the hood Lock the screws L to fasten...

Page 7: ...w the line of shelves it will be necessary to drill a suitable hole in the top shelf only to allow the air ducting pipe to pass through fig 13 2 Direction and position of the ducting fan unit a The hood is normally supplied with the air towards the wall installed with the to the right or left be necessary to change of the ducting fan proceeding as follows Unscrew the screws Turn the ducting the ri...

Page 8: ...ll the way out Remove the protective film P b Rest the lower section of the chimney in its housing on the top of the hood canopy Lower the ducting fan unit until it reaches the wall bracket S and fix it using the screw H provided fig 21 Fit the cover D provided on the wall bracket S fig 22 c Insert gasket G1 found in the accessory bag on the base of chimney stack A so that it adheres perfectly to ...

Page 9: ...y after connection to the power supply 4 5 Connection to power supply and checking of good working order 1 It is absolutely necessary to follow the warnings 3 2 3 3 and 3 4 of paragraph 3 concerning safety measures 2 Loosen the two locking screws and remove the metal cover fig 26 Connect the hood connection to the engine connection fig 27a Correctly place the connectors under the cover and tighten...

Page 10: ...rom licking round from the bottom of the pan this will save energy and will avoid a dangerous concentration of heat 1 4 Always ensure that the appliance is used in accordance with the manufacturer s instructions for the removal of contaminated air and odours during cooking 2 OPERATION Control Panel fig 28 The layout of the control panel is as follows Key Turns the lighting system on and off Key Tu...

Page 11: ...suction motor Press the Speed button for at least 3 seconds until the LEDs flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on WARNING always comply with the maintenance and replacement times indicated in order to avoid a possible risk of fire when the filters are saturated with grease 3 2 Activated charcoal filter 1 Opera...

Page 12: ...ollows Press the Speed button for at least 3 seconds until the LEDs flash in confirmation In any case the saturated filters alarm will only come into operation when the suction motor is turned on WARNING always comply with the maintenance and replacement times indicated in order to avoid a possible risk of fire when the filters are saturated with grease 3 3 Light 1 It consists of 2 20 W halogen sp...

Reviews: