Permanent connection
In the case of a permanent connection it is
necessary that you install a double pole switch
between the appliance and the electricity supply
(mains), with a minimum gap of 3 mm between the
switch contacts and of a type suitable for the
required load in compliance with the current
electrical regulations.
The switch must not break the yellow and green
earth cable at any point.
This operation has only to be performed by a
qualified electrician.
30
Electrical connection
This machine is designed to operate on a 220-230 V,
single-phase, 50 Hz supply.
Check that your domestic electrical installation can
take the maximum load required (2.2 kW), also
taking into account any other appliances in use.
Connect the machine to an earthed socket.
The manufacturer declines any
responsibility for damage or injury through
failure to comply with the above safety
precaution.
Building-in
This appliance has been designed to be built into the
kitchen furniture.
The recess should have the dimensions shown in
picture
A
.
820 min
570 min.
600
596
41
6
176
,
5
81
8
541
195
490
160
120
90
8
515
165
A
600
Preparation and assembly of the door
The machine is originally pre-arranged for the
assembly of a door opening from right to left.
In this case it is sufficient to screw in the hinges (1)
and the counter-magnet (6) provided with the
appliance, at the right level (Fig.
B
).
a) Door
The dimensions of the door should be:
- width
595-598 mm
- thickness
16-22 mm
The height (C-Fig.
C
) depends on the height of the
adjacent furniture's base.
4
1 2
3
6
1
2
3
5
7
B
132995090.qxd 11/7/01 12:06 PM Pagina 30 (Nero/Process Black pellicola)