GB
22
Customer service and spare parts
If you cannot find the remedy for a malfunction in these oper-
ating instructions, please contact your dealer or our cus-
tomer service department and consult the Guarantee card.
Selective ordering of replacement parts can save unnec-
essary travel and costs.
For this reason always provide the following appliance
information:
Model Name
Model Number (PNC)
Serial Number (S-No.)
This information can be found on the rating plate inside
the cabenit on the left hand wall. We recommend that you
enter this information here, so that it is handy if needed.
Technical specifications
The technical data is indicated in the rating plate on the
left side inside the appliance.
If there is a power failure when food is in the
freezer, do not open the door of the freezer
compartment.
The frozen food will not be affected if the power cut
is of short duration (up to 12 hours) and the freezer
compartment is full, otherwise, it is recommended
that the food should be used within a short time (a
temperature increase of the frozen food shortens its
safe storage period).
Installation
Take utmost care when handling your appliance so as not
to cause any damages to the cooling unit with conse-
quent possible fluid leakages.
During normal operation, the condenser and compres-
sor at the back of the appliance heat up considerably.
Always ensure that there is adequate ventilation as a fail-
ure to do this will result in component failure and possible
food loss. See installation instructions.
Important: if the supply cord is damaged, it must be
replaced by a special cord or assembly available from
the manufacturer or its service agent.
Positioning
Unpack the cabinet and check that it is in good condi-
tion and free of any transport damage.
The appliance must not be located close to radiators
or gas cookers.
Avoid prolonged exposure of the appliance to direct
sunlight.
For safety reasons, minimum ventilation must be as
shown in Fig.
Attention:
keep ventilation openings clear of obstruction.
It is necessary that the niche is provided with a con-
duct of ventilation having the following dimensions:
Depth 50 mm
Width 540 mm
The climate classification can be found on the rating
plate, which is located inside the cabinet on the left hand
wall.
The following table shows which ambient temperature is
correct for each climate classification:
Climate
for an ambient
classification
temperature of
SN
+ 10... + 32 °C
N
+ 16... + 32 °C
ST
+ 16... + 38 °C
T
+ 16... + 43 °C
When the ambient temperature is not included with-
in the range indicated for the class of this appliance,
the storage temperature in the appliance cannot be
guaranteed; therefore it is advisable to use the food