What to do if trouble occurs

 

Danger!

 The cooker hood may only be repaired by an authorised

technician.

 

Danger! 

For repair work the appliance must be disconnected from 

the power supply by pulling out the mains plug or unscrewing the 
household fuse.

First check whether there has been any operating error. You can deal with
some problems that occur yourself.

Problem

Cause Remedy

It is not possible to
switch off the cooker
hood.

Electronic component is
defective.

Pull out plug or switch off
fuse,
Call Customer Service.

Halogen lighting
does not work.

Lamp defective

Replace lamp.

LED does not work.

LED defective.

Call Customer Service.

Performance of the
cooker hood is
reduced.

Filters very clogged.

Replace filters.

Several LEDs flash.

Not a defect

see “Cleaning the metal
fat filters”.

Rating label

The rating label can be seen when you have removed the fat filter or the
activated charcoal filters. Please make a note of the following data on the
rating label before or while installing the cooker hood in case you have to
consult our Customer Service:

Serial number:

Model designation:

16

KD 966.1 / KDEM 966.1

Summary of Contents for IKD 966.1

Page 1: ... for use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Instruções de uso e de montagem KD 966 1 KDEM 966 1 537 518 G61 ...

Page 2: ...s and functions For operating your cooker hood For operating the hood with stoves and heating appliances with a naked flame General advice 13 General instructions on use 13 Your appliance at a glance 14 Using the hood 14 Before using your appliance for the first time Switching the lighting On Off Switching on the ventilation Changing the ventilation setting Switching the ventilation off Switching ...

Page 3: ...ly in rooms where a negative pressure of 0 04 mbar is not exceeded This ensures that the fumes from the stove are not sucked back into the room This can be achieved if there are non airtight openings in windows and doors ventilation wall boxes supplying extracting air or other technical devices e g interlock devices so that a sufficient supply of combustion air can flow back into the room When ass...

Page 4: ...es off the hood in the settings 2 to 4 after 10 minutes After switching the hood on press the respective setting button a se cond time With the timer activa ted the control light of the setting selected flashes Press the button 0 1 to switch off the hood before the time lapses Cleaning interval for the fat filters After about 30 hours of operation all the control lights flash at the same time to r...

Page 5: ...re with the holders Insert both filters again To this end insert the two brackets of one cover into the openings provided in the lamp holder press the filter upwards and then push inwards until it is firmly in position If the control lights still flash when the hood is used for the first time af ter cleaning press one of the lower three buttons The counter for the operating hours is then reset to ...

Page 6: ... defective Pull out plug or switch off fuse Call Customer Service Halogen lighting does not work Lamp defective Replace lamp LED does not work LED defective Call Customer Service Performance of the cooker hood is reduced Filters very clogged Replace filters Several LEDs flash Not a defect see Cleaning the metal fat filters Rating label The rating label can be seen when you have removed the fat fil...

Page 7: ...enclosed dowels and screws are suitable for walls made of perfora ted bricks or concrete bricks which are 20 mm thick For solid concrete walls you must use special concrete dowels from a specialist store For solid wooden walls you must use wood screws of sufficient thick ness and length Electric connection The hood is fitted with a normal mains plug and there should therefore be a socket outlet 23...

Page 8: ...y The chimney consists of two parts The upper part has ventilation slits the lower part recesses for the control buttons The recesses for the control but tons must always be at the bot tom The chimney parts can be pulled apart and pushed together again as required Recirculation mode The ventilati on slits must be at the top Extraction mode The ventilation slits must be at the bottom so that they a...

Page 9: ...F Screwing the control element tight Reach through the right hand side of the opening at the bottom of the hood body and tighten the control element with the knurled screws Make sure that all the control buttons protrude slightly forwards out of the chimney Inserting the metal fat filters Before you install the filters again you should read off the serial number and the model designation on the ra...

Page 10: ...pe must not exceed 2 5 m The pipe must be heat insulated or an air trap seal must be installed Extraction into an existing exhaust shaft The exhaust air must only be introduced into an existing exhaust shaft if this is insulated against damp and is not already used for fuel purposes Have the chimney sweep responsible approve the use of the shaft Please note If the extraction channel is led through...

Reviews: