11
INSTALLATION
If this appliance featuring magnetic door seals is to
replace an older appliance having a spring lock (latch) on
the door or lid, be sure to make that spring lock
unusable before you discard the old appliance. This will
prevent it from becoming a death-trap for a child.
Positioning
The appliance should be installed well away from
sources of heat such as radiators, boilers, direct
sunlight etc.; best performance is obtained with
ambient temperature b16
°
C and +32
°
C
(class N) or b10
°
C and +32
°
C (class SN).
The class of your appliance is shown on its rating
plate.
For building into kitchen units follow the special
“Building-in” instructions given.
Electrical connection
Before plugging in, ensure that the voltage and
frequency shown on the serial number plate
correspond to your domestic power supply.
Voltage can vary by
±
6% of the rated voltage.
For operation with different voltages, a suitably
sized auto-transformer must be used.
The appliance must be earthed.
The power supply cable plug is provided with a
contact for this purpose.
If the domestic power supply socket is not earthed,
connect the appliance to a separate earth in
compliance with current regulations, consulting a
specialist technician.
The Manufacturer declines all responsibility if the above
safety precautions are not observed.
This appliance complies with EEC directive number
87/308 of 2/6/87 relative to radio interference
suppression.
This appliance complies with the following
E.E.C. Directives:
-
73/23 EEC
of 19.2.73 (Low Voltage Directive) and
subsequent modifications;
-
89/336 EEC
of 3.5.89 (Electromagnetic
Compatibility Directive) and subsequent
modifications.
Cleaning the interior
Before using the appliance for the first time, wash
the interior and all internal accessories with
lukewarm water and some neutral soap so as to
remove the typical smell of a brand-new product,
then dry thoroughly.
Do not use detergents or abrasive powders, as
these will damage the finish.
Building-in instructions
Dimensions of housing
The appliance’s door has been locked in position for
transport by means of pins on both sides.
According to the door opening direction, remove relevant
pins at the top and at the bottom.
Fig. 1
For safety
reasons,
minimum
ventilation must
be as shown in
Fig. 1.
Attention: keep
ventilation
openings clear of
obstruction
.
Fig. 2
Push appliance
into housing until
stop strip (A)
touches the
kitchen unit.
Fig. 3
If after having
carried out the
operation just
described there is
still some space
left between the
appliance and the
kitchen unit, fit
the trimming
provided
together with the appliance, on the stop strip (A).
Model
Height of
housing
Depth of
housing
Width of
housing
IK 153-3 Z
880 mm
550 mm
560 mm
50 mm
min.
cm
2
200
200 cm
2
min.
D567
A
D022
D265
A