Küppersbusch GMS 6540.0 E-UL Instructions For Use Manual Download Page 12

12

BURNER ARRANGEMENT ON THE HOT PLATE

TABLE

FIG. 10

CONVERSIONS

11) REPLACING THE INJECTORS

The burners can be adapted to different types of

gas by mounting injectors suited to the type of gas

in question. To do this, first remove the burner tops

using a wrench “B”. Now unscrew injector “A” (see

fig. 10) and fit a injector corresponding to the

utilized type of gas in its place.

It is advisable to strongly tighten the injector in

place.

After the injectors have been replaced, the

burners must be regulated as explained in

paragraphs 10. The technician must reset any

seals on the regulating or pre-regulating devices.

The envelope with the injectors and the labels can

be included in the kit, or at disposal to the

authorized customer Service Centre.

For the sake of convenience, the nominal rate table

also lists the heat inputs of the burners, the

diameter of the injectors and the working pressures

of the various types of gas.

BURNERS

GAS

NORMAL

PRESSURE

inches water

column

INJECTOR

DIAMETER

1/100 mm

NOMINAL HEAT

INPUT (Btu/h)

DESCRIPTION

Min.

Max.

1

ULTRA RAPID

PROPANE HD - 5

NATURAL GAS

11

7

94

176

4400

4400

11000

11000

2

RAPID

PROPANE HD - 5

NATURAL GAS

11

7

91

155

2500

2500

10000

10000

3

SEMIRAPID

PROPANE HD - 5

NATURAL GAS

11

7

70

120

1500

1500

6100

6100

4

SEMIRAPID

PROPANE HD - 5

NATURAL GAS

11

7

70

120

1500

1500

6100

6100

5

AUXILIARY

PROPANE HD - 5

NATURAL GAS

11

7

53

90

1200

1200

3550

3550

Summary of Contents for GMS 6540.0 E-UL

Page 1: ...cturer shall not be held responsible for any damages to persons or property caused by incorrect installation or use of the appliance The Manufacturer shall not be held responsible for any inaccuracies in this handbook due to printing or transcription errors the designs in the figures are purely indicative The Manufacturer also reserves the right to make any modifications to the products as may be ...

Page 2: ... Btu h 6 Enamelled steel pan support 2F 7 Enamelled steel pan support central 8 Burner n 1 control knob 9 Burner n 2 control knob 10 Burner n 3 control knob 11 Burner n 4 control knob 12 Burner n 5 control knob 13 Electric ignition button Attention this appliance has been manufactured for domestic use only and it employment by private person TYPES GMS 6540 0 E UL TYPES GMS 9551 0 E UL ...

Page 3: ...g the appliance Save the orifices removed from the appliance for future use When a flexible service cord of the grounding type is provided to connect the appliance to a line voltage electrical supply the instructions shall also include the intent of the warning statement specified in 1 29 12 The maximum depth cabinets installed above cooking tops be 13 in 330 mm Keeping appliance area clear and fr...

Page 4: ...nsumption use adequate pans for each burner consult the following table and fig 2 When the pan comes to the boil set the knob to the reduced rate position small flame fig 1 Always place a lid on the pans Use only pan with a flat bottom WARNINGS burners with flame failure device may only be ignited when the relative knob has been set to the Full on position large flame fig 1 Matches can be used to ...

Page 5: ...d Intensive and lengthy use of the appliance may require additional ventilation This can be achieved by opening a window or by increasing the power of the mechanical exhausting system if installed WARNING NEVER use this appliance as a space heater to heat or warm the room Doing so may result in carbon monoxide poisoning and overheating ot the oven ...

Page 6: ...k salted water lemon or tomato juice from remaining in contact with the enamelled surfaces for long periods of time WARNINGS comply with the following instructions before remounting the parts check that burner head slots T fig 3 have not become clogged by foreign bodies Check that enamelled burner cap C fig 3 have correctly positioned on the burner head It must be steady The exact position of the ...

Page 7: ...l which prevents liquid from getting into the cabinet Strictly comply with the following instructions in order to correctly apply this seal detach the seals from their backing checking that the transparent protection still adheres to the seal itself Overturn the hot plate and correctly position seal E fig 6 under the edge of the hot plate itself so that the outer side of the seal perfectly matches...

Page 8: ...e appliance on purchase Assemble the regulator noting the gas flow direction and transition pieces supplied with the appliance in accordance with below figure The transition piece on the supply side of the regulator must be provided by the installer Unions compatible with the hose fittings must be used and connections tested for gas leaks Ensure the supply connection point is accessible with the a...

Page 9: ...the data label to the cable Fit the wires following figure 8 taking care of respecting the following correspondences Letter L live wire Letter N neutral wire earth symbol green or yellow green wire Never use reductions adapters of shunts for connection since these could create false contacts and lead to dangerous overheating The outlet must be accessible after the built in When the appliance is co...

Page 10: ...hout overlapping Evenly and securely fix the seal to the hot plate pressing into place with the fingers and remove the strip of protective paper from the seal and set the plate into the hole made in the cabinet Fix the hob with the proper brackets S and fit the prominent part into the porthole H on the bottom turn the screw F until the bracket S stick on the top fig 7 The prospective walls left or...

Page 11: ...move knob M fig 9 of the tap which is simply pressed on to its rod Insert a small screwdriver D into hole C fig 9 and turn the throttle screw to the right or left until the burner flame has been adequately regulated to the Reduced rate position Check that the flame does not go out when the knob is sharply switched from the Full on to the Reduced rate position It is understood that only burners ope...

Page 12: ...ulating devices The envelope with the injectors and the labels can be included in the kit or at disposal to the authorized customer Service Centre For the sake of convenience the nominal rate table also lists the heat inputs of the burners the diameter of the injectors and the working pressures of the various types of gas BURNERS GAS NORMAL PRESSURE inches water column INJECTOR DIAMETER 1 100 mm N...

Page 13: ...th automatic ignition systems It is advisable to change seal D whenever a tap is replaced to ensure a perfect tightness Greasing the taps see fig 15 16 If a tap becomes stiff to operate it must be immediately greased in compliance with the following instructions remove the tap Clean the cone and its housing using a cloth soaked in diluent Lightly spread the cone with the relative grease Fit the co...

Page 14: ...S 7 inches water column Σ Qn Natural Gas 25750 Btu h Voltage 120 V AC Frequency 60 Hz TECHNICAL DATA ON THE DATA LABEL 5 BURNERS 90 PROPANE HD 5 11 inches water column NATURAL GAS 7 inches water column Σ Qn Natural Gas 36750 Btu h Voltage 120 V AC Frequency 60 Hz ...

Page 15: ...est After Sales Service Center whenever repairs or adjustments are required specifying the type of fault and the model of the appliance in your possession Please also note that genuine spare parts are only available from our After Sales Service Centers and authorized retail outlets The above data are printed on the data label put on the inferior part of the appliance and on the packing label The a...

Page 16: ...Kuppersbusch USA 1883 Massaro Blvd Tampa FL 33619 Toll 800 459 0844 P 813 288 8890 F 813 288 8604 ...