Küppersbusch GKS 324.0 Installation Instructions Manual Download Page 5

GKS 324.0/GKS 644.0 installation Natural gas

5

If several cook tops are installed next to each other, please observe the min-
imum distances between the cuts into the counter top indicated in the drawing.

Connecting the appliance to the gas supply

[

The gas cook top may only be operated if the supplied gas pressure reg-
ulator and a shut-off valve (not supplied) are connected in a correct way.

F

The gas supply pressure stated shall be at least 7 inch water column for 
checking the regulator setting!

Make sure the gas and the gas supply pressure are correct. The correct gas 
supply pressure is 6 inch water column.

The pipe for the gas connection is located at the center of the underside of 
the appliance.

The connection parts must be positioned so they can’t heat up or become 
damaged while the appliance is in operation. They also can’t come into contact 
with the movable parts of the kitchen elements.

– Look at the adhesive label located on the underside of the appliance to see 

which type of gas the built-in cook top is set for.

– Connect the pipe for the gas connection with the enclosed adapter.

– Connect the gas pressure regulator via a rigid or a flexible conductor with 

the adapter. 
Make sure the regulator is installed in the right direction.

– Check the gas pressure regulator for its setting and the appliance for the 

absence of leakage.

– Connect the gas pressure regulator with the shut off valve and connect this 

with the gas supply.

Leak testing

[

Before the appliance is put into operation, it must be checked by a gas 
technician to make sure it’s functioning properly and there is no gas leak-
age. Leak testing of the appliance shall be conducted according to this 
installation instruction!

[

Absolutely no leakage should occur, otherwise there is a danger of 
fire or explosion depending upon conditions. Never use if leakage 
is detected.

[

Do not use a flame to check for leakage!

[

The appliance and its individual shutoff valve must be disconnected from 
the gas supply piping system during any pressure testing of that system 
at test pressures in excess of 1/2 psi (3.5kPa).
For pressure testing of that system at test pressures equal to or less than 
1/2 psi (3.5 kPa) the appliance must be isolated from the gas supply pip-
ing system by closing its individal manual shut-off valve.

[

The maximum gas supply pressure in accordance with the inlet pressure 
rating of the gas appliance pressure regulator supplied (10 inch water 
column) is 13 inch water column.

– Check carefully for gas leaks immediately after the regulator has been in-

stalled and the gas turned on. Do this before attempting to operate the ap-
pliance or other gas burning device. Use a rich soap solution (or other 
accepted leak tester) around the diaphragm flanges, bottom plate, vent 
opening, seal cap pipe connections, and all other joints. Wipe clean with a 
damp rag.

Connecting the appliance to the electricity supply

The appliance must be electrically grounded in accordance with local codes or, 
in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.

A grounded, shockproof socket is required for electrical connection. Electrical 
connection must be carried out in conformity with all local and national 
codes.
The plug for the appliance is rated for 120 V / 60 Hz. The power consump-
tion is 0.7 VA.
The connection parts must be positioned so they can’t heat up or become 
damaged while the appliance is in operation.

View of counter 
top

Detail

Cook top

Work top

Summary of Contents for GKS 324.0

Page 1: ...s for Natural Gas Unit GKS 644 0 GKS 324 0 072428 I21 USA Dear Consumer Please keep this manual in a safe place and pass it on to future reference Dear Installer Please leave this instruction with the...

Page 2: ...chnician during normal business hours What Isn t Covered Service by an unauthorized agency will not be reimbursed Likewise the warranty doesn t cover any damage or repairs due to service performed by...

Page 3: ...f turning on or shutting off gas to the appliance The maximum gas supply pressure in accordance with the inlet pres sure rating of the gas appliance pressure regulator supplied 6 inch water column is...

Page 4: ...4 GKS 324 0 GKS 644 0 Installation Natural gas GKS 324 0 Appliance height GKS 644 0 Appliance height...

Page 5: ...the appliance shall be conducted according to this installation instruction Absolutely no leakage should occur otherwise there is a danger of fire or explosion depending upon conditions Never use if...

Page 6: ...down Place the burner cover the saucepan support s and attachment carefully in the correct position Pin up the control knobs Insert plug into the socket Initial start up Turn on the gas connection tap...

Page 7: ...could damage the frame of the cook top Press the cook top out of the recess from underneath to dismantle Replacement Insert the rear edge of the cook top and carefully lower At the same time press in...

Page 8: ...K PPERSBUSCH 112 N East Street Suite C Tampa Florida 33602 Telephone 813 229 7096 Fax 813 229 0982 Customer Care line 1 800 459 0844 www kuppersbuschusa com K PPERSBUSCH is a brand of Teka USA Inc...