background image

TECHNICAL SPECIFICATIONS

19

t

The technical data is indicated in the rating plate on the left side inside the appliance.

INSTALLATION

lf this appliance featuring magnetic door seals is
to replace an older appliance having a spring lock
(latch) on the door or lid, be sure to make that
spring lock unusable before you discard the old
appliance. This will prevent it from becoming a
death-trap for a child.

Positioning

The appliance should be installed well away from
sources of heat such as radiators, boilers, direct
sunlight etc.
Best performance is obtained with ambient
temperature b18°C and +43°C (class T);
+18°C and +38°C (class ST); +16°C and +32°C
(class N); +10°C and +32°C (class SN).
The class of your appliance is shown on its rating
plate.

For building-in and door reversibility refer to the
relevant instructions.

Electrical connection

Before plugging in, ensure that the voltage and
frequency shown on the serial number plate
correspond to your domestic power supply.
Voltage can vary by ±6% of the rated voltage.
For operation with different voltages, a suitably sized
auto-transformer must be used.

Important

The appliance must be earthed.
The power supply cable plug is provided with a
contact for this purpose.
If the domestic power supply socket is not
earthed. connect the appliance to a separate
earth in compliance with current regulations,
consulting a specialist technician.

The Manufacturer declines all responsibility if the
above safety precautions are not observed.

Attention!
It must be possible to disconnect the appliance

from the mains power supply; the plug must
therefore be easily accessible after installation.

TAW1MERA

This appliance complies with EEC directive
number, 87/308 of 2/6/87 relative to radio
interference suppression.

This appliance complies with the following
E.E.C. Directives:

- 73/23 EEC of 19.2.73 (Low Voltage Directive) and

subsequent modifications;

- 89/336 EEC of 3.5.89 (Electromagnetic

Compatibility Directive) and subsequent
modifications.

Door reversal (where necessary)

Warning!

When changing the side of the door opening,

the appliance may not be connected to the
mains. Remove plug from the mains
beforehand.

Summary of Contents for FKE 167-5

Page 1: ...emploi Belangrijk Beslist lezen en bewaren Importante necessario leggere attentamente queste istruzioni e conservarle con cura Importante Leerlas imprescindiblemente y guardarlas Integrierte Einbau K...

Page 2: ...6 Movable shelves 16 Positioning the door shelves 16 Hints 17 Hints for refrigeration 17 Maintenance 17 Defrosting 17 Periodic cleaning 18 Periodic of non operation 18 Interior light 18 Customer servi...

Page 3: ...ts This appliance contains hydrocarbons in its cooling unit maintenance and recharging must therefore only be carried out by authorised technicians Use The domestic refrigerators and freezers are desi...

Page 4: ...failure to do this will result in component failure and possible food loss See installation instructions Parts which heat up should not be exposed Wherever possible the back of the product should be...

Page 5: ...ure the number of times the door is opened the quantity of food stored and the location of the appliance Warning If the ambient temperature is high the thermostat knob is on the coldest setting higher...

Page 6: ...r Meat can only be stored safely in this way for one or two days at the most Unplug the appliance before carrying out any maintenance operation Warning This appliance contains hydrocarbons in its cool...

Page 7: ...re If the door is open and the light does not come on check that the bulb is properly screwed in if it still does not work replace the bulb with one of the same power The maximum rating is shown on th...

Page 8: ...Voltage can vary by 6 of the rated voltage For operation with different voltages a suitably sized auto transformer must be used Important The appliance must be earthed The power supply cable plug is p...

Page 9: ...shown in Fig Attention keep ventilation openings clear of obstruction It is necessary that the niche is provided with a conduct of ventilation having the following dimensions Depth 50 mm Width 540 mm...

Page 10: ...ted only when the door is hinged on the left please carry out the following installation steps on the opposite side as appropriate FAL1MERA 1 Performing adjustments 3 Apply joint cover fillets 4 Fit v...

Page 11: ...the appliance into place GF1MERA SAB1ME 6 Install screw head caps 7 Attach door panel PL12 PL13 8 Apply door handle 9 Inserting the appliance door TE1MERA GAU4ME 10 Aligning the appliance door where...

Page 12: ...K ppersbusch Vertriebsgesellschaft mbH Postfach 10 01 32 45801 Gelsenkirchen Hausanschrift K ppersbuschstr 16 45833 Gelsenkirchen Telefon 02 09 4 01 0 Teletex 20 931 810 Telefax 02 09 4 01 3 03...