Operation
34
GB
120 Min.
10 Min.
4.16 Keep-warm function
With the keep-warm function you keep food warm with a
specifi c temperature. The respective cooking zone is ope-
rated at a low power level.
1. Turn the regulator to the right into the required position:
corresponds to about 42°C
corresponds to about 70°C
corresponds to about 94°C
2. The keep-warm function is available for 120 minutes,
after which the cooking zone will be switched off .
4.17 Power boost
The power boost setting makes additional power available
for induction cooking zones. A large quantity of water can
be brought to the boil very quickly.
1. Turn the respective regulator to the right until they stop
and a signal sounds. The power setting display shows
. The power boost will now be activated.
2. After 10 minutes the power boost setting will switch off
automatically. The will go off and the power level will
switch down to 9.
Please note:
Switch off the cooking zone or set the required power level
to prematurely switch off the power boost setting.
4.18 Power management
For technical reasons two cooking zones always comprise
a module and have a maximum power level.
If this power range is exceeded when a higher power
setting level or the power boost function is switched on the
power management system will reduce the power setting
of the corresponding cooking zone of the module.
The display for this cooking zone will initially blink, after
which the highest-possible power setting will be consis-
tently displayed.
Modules (power management)