background image

Service Manual

5

For internal use only

2.

Accessing the components inside the hood

Two models of the hood are produced: stainless steel with Soft Touch electronic controls and stainless
steel/glass with Touch Control electronic controls.

The  middle  panels  of  both  models  can  be  opened  when  pulled  out.  This  gives  you  access  to  the
components inside the hood.

The panel is removed by means of the movable hinge peg.

2.1

Removing the controls

1.

Remove  the  two  screws  that  fasten  the  front  of  the  hood  to  its
casing.

2.

Use a small screwdriver to remove the springs on the front (on
the left and right) from the casing section.

3.

Pull out the front.

4.

Screw  out  the  two  screws  on  the  back  of  the  front  part  which
fasten the controls to the clamp.

Summary of Contents for KD6590.0GE

Page 1: ...Cooker hoods KD6590 0GE and KD9590 0GE Accessing the components...

Page 2: ...Manual H5 85 04 Responsible U Laarmann K PPERSBUSCH HAUSGER TE AG E mail uwe laarmann kueppersbusch de Tel 0209 401 732 Customer Service Fax 0209 401 743 Postfach 100 132 Date 18 06 2013 45801 Gelsen...

Page 3: ...g the components inside the hood 5 2 1 Removing the controls 5 2 2 Accessing the electronic unit and the transformer 6 2 3 Accessing the halogen lamp 6 3 Circuit diagram 7 4 Controls 8 5 Filters 10 5...

Page 4: ...l current circuit breaker must always be used The earthed conductor resistance may not exceed the resistance specified in the standard It is vital for ensuring the safety of persons and the functionin...

Page 5: ...ls can be opened when pulled out This gives you access to the components inside the hood The panel is removed by means of the movable hinge peg 2 1 Removing the controls 1 Remove the two screws that f...

Page 6: ...nside the hood can be accessed The ATF circuit board and the transformer of appliances fitted with an Athena electronic system are located in a box within the Easy Cube 2 3 Accessing the halogen lamp...

Page 7: ...Service Manual 7 For internal use only 3 Circuit diagram...

Page 8: ...ates the motor in the air circulation mode at a speed which enables an extraction rate of 100 m h for 10 minutes every hour after which time the motor is stopped Shows 24 and all the segments shown on...

Page 9: ...ep key A pressed for approx 5 seconds in order to activate or deactivate the keyboard lock The procedure is always confirmed with a beep and when the motor bar is shown on the display H Reduces the in...

Page 10: ...ecome discoloured with time this will not have any impact on the effectiveness of a filter 4 When remounting the filters make sure that the handle is on the visible exterior 5 Close the Comfort Panel...

Page 11: ...e the alarm for the charcoal filter setting is DEACTIVATED 5 2 2 Replacing the charcoal odour filter Resetting the saturation display 1 Switch off the lighting and the fan motor 2 Press key G for at l...

Reviews: