Installation above the oven 
EEB 9600.0

The oven must be positioned on a secured shelf be-
tween two cabinets. Shelves (approximately 19mm/ 
9/16" thick) must be attached to the adjacent cabi-
nets on both sides so the oven can be clipped in at 
the sides.

Please review the installation instructions for the 
model EEB 9600 for installation dimensions and in-
stallation.

Be sure to install a 
stainless steel filler panel 
(acc. No. 454) between the 
Cook-Center and the oven. 
The stainless steel filler 
panel is required and sold 
separately.

Electrical connection

■ 

Observe all guidelines and regulations from your local electric code.

■ 

You should not be able to touch insulated components when operating the 
appliance.

■ 

The power supply should be a 240 volts system, 2-wire with ground, or a 
120/240 volts system, 3-wire with ground.

Electrical diagram
for a 240 volts system,
2-wire with ground:

Electrical diagram
for a 120 / 240 volts system, 
3-wire with ground:

■ 

Be sure to install an appropriate conduit box (not furnished) to connect the 
cook top. Only a professional electrician or certified technician should install 
a conduit-box or replace the connection cable.

■ 

Don’t shorten the conduit to facilitate service! The conduit should be routed 
to permit the removal of the cooking surface.

■ 

A circuit breaker or fuse is recommend, having amperage as noted in this 
chapter. Fuse both sides of the line!

■ 

The conduit-box can be mounted under the countertop below the cooking 
surface or in a side cabinet in the wall. Do not mount it above the cooking 
surface!

■ 

Be sure the conduit and the conduit box cannot be touched or damaged 
after installation!

Connection

to a conduit-box (not supplied accessory!)

Total rating

8.3 kW, fuse current: 40 A

Electrical connection

240 V, 60 Hz

Summary of Contents for KC 906.2

Page 1: ...Installation instructions Important Save for the local electrical inspector s use KC 906 2 072445 I31...

Page 2: ...rge All warranty service will be provided by an authorized technician during normal business hours What Isn t Covered Service by an unauthorized agency will not be reimbursed Likewise the warranty doe...

Page 3: ...cooking center must be installed between two side cabinets Make sure all components surrounding the oven can resist temperatures of at least 100 C 210 F These include varnishes edge bands plastic surf...

Page 4: ...wire with ground or a 120 240 volts system 3 wire with ground Electrical diagram for a 240 volts system 2 wire with ground Electrical diagram for a 120 240 volts system 3 wire with ground Be sure to...

Page 5: ...conduit to the conduit box Fit the appliance in Fasten the appliance onto the supporting rails using 4 2 x 7 mm screws Use silicon to seal the appliance on the back and on the two sides Installing ac...

Page 6: ...ting rails Adapt the pot grid width if necessary IIf the slide out grid doesn t fit into the corner because it s too wide or if there s too much space after it s been inserted the slide out grid width...

Page 7: ...the stainless steel filler panel acc no 454 Mark the screw positions for the cabinet floor and the door hinges A must be the same height as B When screwing in the screws leave space for the floor of...

Page 8: ...K PPERSBUSCH 112 N East Street Suite C Tampa Florida 33602 Telephone 813 229 7096 Fax 813 229 0982 Customer Care line 1 800 459 0844 www kuppersbuschusa com K PPERSBUSCH is a brand of Teka USA Inc...

Reviews: