Mounting above a stove
Furnace for solid fuels
In a solid fuel stove which can fire out (sparks) is the fitting of the hood only allowed when
the furnace is closed and its shielding is not removable.
Gas stove
The minimum distance between the gas stove and the cooker hood is 750mm. If the
manufacturer of the stove is recommending a lager distance please follow this advise.
Electric hob
The minimum distance between the gas stove and the cooker hood is 650mm. If the
manufacturer of the stove is recommending a lager distance please follow this advise.
Gas hob
The installation of the gas hob with a minimum distance of 750mm to the cooker hood is
only allowed if the following, single values for the thermal load are not exceeded.
load of one cooking zone max. 3,0 kW
load of all cooking zones
max. 8,3 kW
load of the cooker
max. 3,9 kW
Always follow the installation requirements and instructions of the cooker manufacturer!
Control
The cooker hood has the following functions:
Button 1:
low level
Button 2:
average level
Button 3:
high level
Button 4:
intensive level, after 3 minutes it will automatically switch back to high speed.
Button 5:
Automatic delay stop – Pressing this key will switch the motor to highest
speed, after every three minutes it will switch to an lower speed until it switches off.
Button 6:
light on/off
Button 7:
Grease filter saturation indicator – when lit the grease filter must be cleaned,
after cleaning the light can be reset by pressing and holding the key for 5 seconds.