GWS 457.0
23
Appliance installation
– Installation of the appliance is carried out in reverse order to removal.
[
Prior to tightening the fixing screw
of the injector tube, it is essential
to adjust the primary ventilation duct
“A”
.
See section “Replacing the full-flame injectors” on page 22.
Re-installing the hob
– Check the gasket.
– Position the hob on the left side
(1), align it (2) and clip it in (3).
Be careful not to pinch the
connecting cable!
– Attach the control knob.
– Put on the intermediate ring, the burner ring, the burner cap and the pan
support, ensuring that they are properly positioned. The peg must engage
in the slot.
Functional test
[
A functional test must be carried out when re-installation of the appliance
has been completed!
– Put the appliance into operation in accordance with these operation
instructions.
– Check to ensure that the appliance is gas-proof (see DVGW – German
Association of Gas and Water Industry – worksheet no. G600 (DVGW TRGl
1986/96 / TRF 1996).
– Carry out regular checks to ensure cross-ignition and a steady burner flame
(for a low flame too).