H2-120-01-01
19
For internal use only
6.
Conversion to a Different Gas Type - Table of Injector
Diameters
The appliance has been factory-set to natural gas G20, 2H, 2E, 2E+.
All appliances marked with G20 are to be operated in the Wobbe index range (Wo) from 11.3 kWh/m
3
to 15.2 kWh/m
3
without changing the setting.
If the setting is changed, the new setting has to be marked.
6.1
Accessory Numbers of the Injector Conversion Kits
6.2
Changing the Main Injectors
Close the gas tap! Pull out the mains plug!
Check the replaceable injectors according to table “Table of injector diameters”! Make sure that
the correct injector is used for each burner.
Dismantle hob and remove glass ceramic plate
♦
Press the hob out of the worktop from below and remove it.
♦
Remove knobs.
♦
Remove burner covers, the saucepan support(s)
and unscrew burner flange.
♦
Loosen the srews on the side of the case and
remove the glass ceramic plate.
Gas type, pressure
Injector kits
Natural gas H, E, E+
G 20 (20/25 mbar)
Natural gas LL
G 25 (20 mbar)
acc. No. 703
Natural gas NL
G 25 (25 mbar)
acc. No. 704
LPS Butane/Propane
G 30 (50 mbar)
acc. No. 701
LPG Butane/Propane
G 30 (28-30/37 mbar)
acc. No. 702