H2-50-02
21
For internal use only
Order numbers for the injector sets:
Liquid gas / Propane / Butane G30/31 50 mbar
Spare-part no. 542160
Liquid gas / Propane / Butane G30/31 30 mbar
Spare-part no. 542161
Liquid gas / Propane / Butane 3BP/G30 37 mbar
Spare-part no. 542162
Natural gas (standard) G20 20 mbar
Spare-part no. 542283
Natural gas NL (standard) G25 25 mbar
Spare-part no.
7.3
Setting the minimum volume of gas for the cooking zone
burners
The procedure for entering the minimum levels enables the pre-determined minimum gas volume to be
changed. Each burner is adjusted to the existing type of gas to which the hob is connected.
The appliance must be ready for operation in this case and the cooking zone burners must all be
switched off.
•
Model GKE 6840.0M:
Press and hold the minus (1) and plus (2) keys of the burner at the front left and
the minus (7) and plus (8) keys of the burner at the front right simultaneously.
•
Model GKE 9851.0M:
Press and hold the minus (1) and plus (2) keys of the burner at the front left and
the minus (9) and plus (10) keys of the wok burner simultaneously.