14
H2-50-02
For internal use only
5.
Installation
5.1
Important installation instructions
The appliance can be installed with a tall unit on one side (on the right or left of the hob). The minimum
clearances shown on the installation diagram must be maintained.
The rear panel and the adjacent surfaces around the hob must be able to withstand an excessive
temperature of 65K. The adhesive connecting the plastic surface and the unit must be able to withstand
temperatures of at least 150°C to ensure that the covering does not come off the unit.
The appliance must be installed in compliance with relevant regulations.
Dimensions to be maintained (in mm)
Table 2:
A
B
C
GB
E
4 cooking zones (60)
553
475
62.5
62.5
55 min.
5 cooking zones (90)
833
475
62.5
62.5
55 min.