Service Manual
29
For internal use only
High voltage transformer
• Secondary winding terminal is on short circuit.
• The transformer windings are on open circuit.
• If the fuse does not blow immediately
but just after some seconds, then
one of the transformer terminals
maybe on short circuit-> Replace the
high voltage transformer.
• Check the continuity of the primary
and secondary coil. If there isn’t any
continuity, the transformer is
defective. Replace the high voltage
transformer.
High voltage capacitor
• Defect isolation between the capacitor terminals.
• Capacitor on short circuit.
• Check the continuity between the
terminals of the transformer. If there
is continuity, the capacitor is
defective. Replace the high voltage
capacitor.
• Check the continuity between the
terminals of the capacitor and the
carcass, with the cables
disconnected. If there is continuity,
the capacitor is defective. Replace
the high voltage capacitor.
Component
Possible cause
Possible repair measures