17
english
Before seeking technical assistance carry out the following checks first:
Defect
Possible cause
Solution
The extractor does not
work
The cable is not connected
Connect the mains cable
No current is reaching the
plug
Revise/repair the electricity circuit
The extractor does not
blow
enough
or
vibrates
Filter saturated with grease
Clean or substitute the filter
Outlet obstructed
Eliminate obstructions
Inadequate air conduit
Contact the installer and follow instructions of
this manual
The lamps do not light
Lamp broken
Contact the Customer Service
ILCOS D CODE: DSL-6-S-500
Height above gas hob: 75 mm minimum.
NEVER PLACE THE COOKER HOOD OVER
AN EYE-LEVEL GRILL.
This appliance must be connected by a
competent person, using fixed wiring via a
DOUBLE POLE SWITCHED FUSED SPUR
OUTLET.
This appliance is not intended for use by
young children or infirm persons without
supervision.
Young children should be supervised to
ensure that they do not play with the
appliance.
We recommend that the appliance is
connected by a qualified electrician, who is a
member of the N.I.C.E.I.C. and who will
comply with the I.E.E. and local regulations.
Should the color of the wires in the mains lead
for the appliance not correspond with the
colored markings identifying the terminal in
your spur box proceed as follows:
The wire which is colored blue must be
connected to the marked N (Neutral) or
colored Black.
The wire which is colored brown must be
connected to the marked L (Live) or colored
Red
Where available (see installation), the wire
which is colored yellow/green must be
connected to the marked
or colored
Yellow/Green.
If the cooker hood is installed for use above a
gas appliance then the provision or ventilation
must be in accordance with the Gas Safety
(Installation & Use) Regulations 1984 and the
relevant
Building
Regulations.
Detailed
recommendations are contained in the
following British Standard Codes of Practice
BS6172, BS5440 and BS6891 Current
Edition.
Summary of Contents for DW7100.0E
Page 41: ...41 III...
Page 42: ...42 o 60cm 65cm 4Pa 4 x 10 5 bar 4 2 90...
Page 43: ...43 LED Teka...
Page 44: ...44 3 5 1 2 3 4 1 2 Timer 15 3 LED 40 C...
Page 45: ...45 2 F 3 6 12 5cm ILCOS D CODE DSL 6 S 500...
Page 46: ...46 2012 19 EU WEEE...
Page 47: ......
Page 48: ......
Page 49: ......
Page 50: ......
Page 51: ......
Page 52: ......
Page 53: ......
Page 54: ......
Page 55: ......