Maintenance

15.

***************************************************

***************************************************

Any service procedure not described here should be
referred to a qualified technician.

Disconnect the fan from power before removing anything.

Cleaning

Clean the outside of the fan with a damp cloth only.
Do not use solvents.
Periodic cleaning of the fan blades and grills is
necessary to maintain peak performance. Cleaning
intervals will depend on the  operating environment.
Inspect the fan regularly for dust and smoke residue
buildup, and clean as soon as there is significant
dirt buildup on fan blades or at the first signs that
airflow through grills maybe restricted.Use a soft 
brush and vacuum to clean grills and fan blades.

Cleaning Steps

1. Disconnect the fan from power.
2. Remove the four cross-head screws and lift the grill.
3. Clean the housing and blade.
4. After cleaning, replace the grill and screws,
   ensuring that screws are securely tightened.

Replacing the Fuse

The main fuse can be replaced by the user if necessary.
An indication that the main fuse may have blown is that
the power LED does not light when the power is applied.
Never bypass the fuse or replace it with one of another
size of rating. To replace the main fuse:
1. Disconnect the power cable from the fan.
2. Screw off the main fuse holder.
3. Replace the fuse with one of the same rating and
   type. 250V,10A vfuse.
4. Replace the fuse holder and reconnect to power.

If the fuse blows repeatedly, disconnect the machine
from power and contact your dealer for service.

Summary of Contents for DIGI-FAN DF-500

Page 1: ......

Page 2: ...l address kupo seed net tw To obtain more product related information please do not hesitate to contact KUPO CO LTD HEAD OFFICE TAIPEI 6F NO 4 LANE 609 SEC 5 CHUNG SHIN RD SAN CHUNG TAIPEI TAIWAN TEL...

Page 3: ...ill for creating focus wind effect It can be sitting on floor by its own floor stand or rigging through the TVMP stud in the center of the bracket Feature 1 sending smoke and haze over long distance 2...

Page 4: ...troller box power supply box bracket body cover motor Back Figure Rear Panel Close Up fuse 10A 250V knob knob switch Front Figure blade DMX controller box supply box cover motor bracket body Back Figu...

Page 5: ...4 Dimension Speed Chart motor speed wind speed Dimension 480 W x 560 H x 460 T mm Weight 12 5kg...

Page 6: ...can hold at least 10 times the weight of the machine Rigging clamps are available as accessories from KUPO Co Ltd Rigging clamps a KCP 836 stud coupler which is incorporate a 16mm 5 8 stud b KCP 844...

Page 7: ...g a stand as a supporting for the Fan is more in Grip Industry Stands supporting Fan to stand alone must be composed by strong legs and can afford the weight of the Fan weight of the fan is 12 5kg so...

Page 8: ...ve Always connect output with the input of the next slave until all slaves are connected up to 9 devices Caution It is necessary to insert the XLR termination plug with 120 Ohm into the input of the m...

Page 9: ...evel Display 2 DMX 512 Address binary digit display 3 Program Select Display 4 Setting Function Select Display Slider Control 1 Fan Speed Level 2 Edit Program 3 Run Program Timing Select the Mode by t...

Page 10: ...green LED will be on showing change the next step fan speed 0 when non selection program mode program 1 5 menu full speed program mode program 6 9 full speed menu DMX512 mode A Function Mode press Me...

Page 11: ...ss setting display 2 digit if LEDs are all on means the 512 channel LED ON 1 DMX512 Address Channel For Example Address9 2 1 see above figure press Enter key to input the latest DMX Address Channel an...

Page 12: ...der level but you would have to press Enter key everytime you input a speed signal if you did not press Enter key the segment could not be memorized up to 124 steps could be record after all the steps...

Page 13: ...an behind or beside the machine as illustrated below photo A B Do not place the fan in front of the fog machine Photo C and direct the output from the fog machine into the fan as this will cause undes...

Page 14: ...ine safely please contact a Kupo for assistance Preventing a Electric Shocks 1 Always ground earth the machine electrically 2 Disconnect the machine from power before removing any components or servic...

Page 15: ...clothing cables or other items cannot be sucked into the fan 2 Disconnect the fan from power before removing any cover or grill Do not operate the fan unless all covers and grills are installed and se...

Page 16: ...grills and fan blades Cleaning Steps 1 Disconnect the fan from power 2 Remove the four cross head screws and lift the grill 3 Clean the housing and blade 4 After cleaning replace the grill and screws...

Page 17: ...rase all then re set DMX address No DMX termination Fit termination plug to last device on DMX link Excessively noisy operation Front grill loose Disconnect the power and tighten grill retaining screw...

Page 18: ...ate 17 Photo 1 1 Photo 1 2 Photo 2 Photo 3 Photo 4 Photo 5 Note If that is necessary to take out the power supply box It is simple just unscrew the 4 screws on rear tubing then pull out the power supp...

Page 19: ...Accessory Photos 18 350 Runway Base STand 310M Low Mighty Stand KCP 703 clamp KCP 836 clamp KCP 100B black KCP 100S silver KCP 844 clamp KS 200 adaptor 28mm 16mm stud...

Page 20: ...w ww stage com tw w ww stage com tw TAIPEI OFFICE 6F NO 4 LANE 609 SEC 5 CHUNG SHIN RD SAN CHUNG TAIPEI TAIWAN TEL 886 2 2999 2906 FAX 886 2 2999 2955 WWW STAGE COM TW KUPO SEED NET COM TW...

Reviews: