GASOLINE GENERATOR SET
USER
’
S MANUAL
Page 1: ...GASOLINE GENERATOR SET USER S MANUAL...
Page 2: ...rmation in this manual We reserve the right to change this product and specifications at any time without prior notice Important Message This manual contains special messages to bring attention to pot...
Page 3: ...5 Use of the Generator Set 10 5 1 Grounding 10 5 2 Wattage of Electrical Devices 10 5 3 Connecting Sequence 10 5 4 Connecting Method 11 5 5 Instructions on AC Usage 11 5 6 Instruction on DC Usage 12...
Page 4: ...ed or partially enclosed places without good ventilation CAN KILL YOU IN MINUTES Generator exhaust contains Carbon Monoxide a colorless odorless but deadly gas Figure 1 Figure 2 Don t operate the unit...
Page 5: ...e and or Explosion Gasoline spillage and its vapors are highly flammable and explosive under certain conditions Be aware to fill fuel after stopping the engine Figure 7 WARNING DANGER Fire and or Expl...
Page 6: ...ge 2 Fuel Tank Cover 3 AC Plug Socket 4 Circuit Breaker 5 Voltmeter 6 Dipstick 7 Ignition Switch 8 Drain Plug 9 Recoil Starter 10 Fuel Switch 11 Air Cleaner 12 Choke Lever 13 Ground Terminal 14 Muffle...
Page 7: ...ies oil as shown in the chart may be used when the average temperature in your area is within the indicated range NOTE Do the check only when the unit stops operation on a level ground Take out the oi...
Page 8: ...over and tighten it well Figure 16 CAUTION Don t add a mixture of gasoline and engine oil used for 2 stroke petrol engines Don t use stale fuel Avoid foreign matters getting into the tank such as dust...
Page 9: ...if the electrolyte level of the battery is between the upper and lower level marked on the battery Figure 20 1 Upper Level 2 Lower Level 3 4 3 Check the specific gravity of electrolyte 3 5 Grounding t...
Page 10: ...dels Turn the key switch to ON position for E start units Figure 24 Pull up the Starting Handle gently until resistance is felt then pull it up rapidly Put back the handle slowly to avoid damage to th...
Page 11: ...g Electric Devices Start Rating Incandescent Lamp Heating Devices X 1 X 1 Incandescent Lamp TV Incandescent Lamp 100W 100VA W 100VA W Fluorescent Lamp X 2 X 1 5 Fluorescent Lamp Fluorescent Lamp 40W 8...
Page 12: ...uaint yourself with the parameters on the Control Panel to ensure correct usage within the rated output of the generator set CAUTION The generator set can work at its rated output only under constant...
Page 13: ...the devices Figure 31 5 6 Instruction on DC Usage Pay special attention to the connection of positive and negative poles in DC application CAUTION The DC output should not be used as power supply for...
Page 14: ...al minutes without load to cool down the generator set 6 2 3 Set the ignition switch to OFF position Figure 35 6 2 4 Set the fuel switch to OFF position Figure 36 WARNING Don t touch the heating compo...
Page 15: ...cessary WARNING Don t carry out any maintenance when the unit is working 7 2 Replacement of Engine Oil Please drain thoroughly the engine oil before the engine completely cooled down to guarantee the...
Page 16: ...e spark plug and its cap Figure 43 Spark Plug recommended F7TC NOTE Screw in half round more after the spark plug compresses its washer if a new spark plug is used Screw in one fourth round more only...
Page 17: ...8 2 Operation methods same as Chapter 6 8 3 Stopping the Unit 8 3 1 For emergency Directly turn the ignition switch key to OFF position 8 3 2 For normal condition 8 3 2 1 Turn off the AC breaker and...
Page 18: ...fresh fuel and adequate amount of gas stabilizer Remove the spark plug and pour into the cylinder a spoon of engine oil pull the recoil start slowly to distribute the oil evenly Re mount the spark plu...
Page 19: ...5 10 1 4 Remove the spark plug check if there is spark jumping out Figure 56 10 1 5 If the generator set still can not be started after the above steps consult your dealer for help Figure 57 10 2 Fail...
Page 20: ...Volt Adjustment AVR Automatic Voltage Regulation Ignition CDI Start Type Recoil Start Recoil start electric start Tank Volume 3 5L 15L 25L Minimum Fuel Consumption 395g Kwh Engine Oil Capacity 0 6L 1...
Page 21: ...20 Kuller Australia Pty Ltd...