• Visual inspection, check for leaks.
• Run the program in T1 mode and look out for irregularities.
8.7
Oil change in A5
Description
The following sections describe the A5 gear oil change for floor-mounted
robots. For ceiling-mounted robots, the procedure is to be applied analo-
gously, but with the drain and filler holes reversed.
Equipment
The following equipment is required:
Designation
Article number
Set of Allen keys
1.5; 2; 2.5; 3; 4; 5; 6; 8; 10 mm
-
Torque wrench
min. 2 Nm to 30 Nm
-
Socket wrench set
-
Collection receptacle
-
KUKA oil pump
0000-180-812
Material
The following material is required:
Designation
Article number
Quantity
Optigear ALR 320
• KR 30 R2100
• KR 50 R2100
• KR 50 R2500
• KR 50 R2500 F
• KR 70 R2100
• KR 70 R2100 F
(
>>>
iliary and oper-
ating materials
used"
Page 336
)
Initial fill-
ing quan-
tity:0.60 l
Tightening torques
The tightening torques can be found under: (
>>>
)
These are valid for screws and nuts where no other specifications are giv-
en.
Screws of strength class 10.9 and higher as well as screws with test cer-
tification may only be tightened once with the rated tightening torque.
When the screws are first slackened they must be replaced with new
ones.
Precondition
• The gear unit is at operating temperature.
• The arm and in-line wrist are in horizontal position.
KR IONTEC
210/344 |
www.kuka.com
MA KR IONTEC V4 | Issued: 11.05.2021
Maintenance
Summary of Contents for IONTEC KR 20 R3100
Page 14: ...KR IONTEC 14 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Introduction...
Page 166: ...KR IONTEC 166 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Planning...
Page 188: ...KR IONTEC 188 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Start up and recommissioning...
Page 310: ...KR IONTEC 310 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 Repair...
Page 340: ...KR IONTEC 340 344 www kuka com MA KR IONTEC V4 Issued 11 05 2021 KUKA Service...