background image

 

 

Alfred Kuhse GmbH 

Phone: +49 4171-798-0 

[email protected] 

Changes without further notice 
reserved. 

An der Kleinbahn 39, D-21423 Winsen (Luhe)  

Fax +49 4171-798-117 

www.kuhse.de

 

 

 

 

Service Manual 

for product: KEA 201 ERSY: 
Control Unit for Emergency Power Gensets 

with Overlapping Synchronisation  

File: 

SA_KEA 201 ERSY_EN_Ver 2016-07-01 

 

 

 

 

1. 

Design 

The control unit is incorporate into the front door of the switchboard. The front meets the protection class 
IP 44 
when installed. The two rows of LEDs are marked with interchangeable labels. The  relay units are 

mounted on the mounting plate and linked to the control unit in the door with the supplied cable. 
The control unit has an optic fibre or a USB interface - switches automatically - for the connection of a PC.  

By  means  of  the  parameterisation  program  P

ARA

W

IN

,  the  following  settings  (password-protected)  and 

analogue readouts are possible. Parameterisation can also be performed at the display. 

 

1.1. 

Parameterisation 

1.

 

Additional Interface CAN 

2.

 

Additional Parameters 

3.

 

Alarm Remote cancelling 

4.

 

Alarms 

5.

 

Analogue Inputs 

6.

 

Analogue Outputs 

7.

 

Battery Monitor 

8.

  CAN

 

0

  

9.

 

Frequency Controller at isolated Operation 

10.

 

Generator Current Monitor 

11.

 

Generator Voltage Monitor 

12.

 

Hardware 

13.

 

Internal Synchronizer 

14.

 

J1939 engine management 

15.

 

J1939 hide analogue values 

16.

 

Mains Voltage Monitor 

17.

 

Modem 

18.

 

ProMerk. Programmable Flags 

19.

 

Relay and Indicator Functions 

20.

 

Speed Monitoring and Control 

21.

 

Sprinkler Operation 

22.

 

Starting and Stopping 

23.

 

Transfer Mains – Generator 

24.

 

Voltage Controller 

Summary of Contents for KEA 201 ERSY

Page 1: ...n optic fibre or a USB interface switches automatically for the connection of a PC By means of the parameterisation program PARAWIN the following settings password protected and analogue readouts are...

Page 2: ...1 Design 1 1 1 Parameterisation 1 1 2 Analogue Readouts 2 2 Amendments 2 3 Contents 2 4 Safety Instructions 3 4 1 Regulations and Instructions 3 4 2 Installation and Commissioning 3 4 3 Connections 3...

Page 3: ...must be taken when connecting the device as it may be destroyed if incorrectly connected All details of the connection specifications must be fulfilled 2 The PE N must be connected for security reason...

Page 4: ...tal parts 8 All coils must be fitted with reverse diodes to prevent high voltage peaks All other coils or inductive loads must also be fitted with suppressor elements The same applies for all relays a...

Page 5: ...of the cursor confirms the selection as it underscores e g 196 now the part of the parameter that is to be modified The chosen parameter cannot be deselected now 6 Select the figure or letter of the p...

Page 6: ...e inductivity of the coil Terminals 1 14 Input for alarms signals Terminal 15 Feedback signal MAINS IS OFF An auxiliary contact NC of the mains CB or contactor is connected to this terminal It shows t...

Page 7: ...erve only as a warning ones If mains fails the consumers are also switched to generator supply Terminal 24 Start enable input Any starting attempt emitted manually or automatically will be interlocked...

Page 8: ...attery voltage monitor Input for pick up Option four analogue inputs which can be fitted with interface cards for PT 100 PT1000 Current loops 0 10 V DC Thermocouple NiCr Ni Temperature and pressure VD...

Page 9: ...201 ERSY_EN_Ver 2016 07 01 doc 9 12 Alfred Kuhse GmbH Phone 49 4171 798 0 kuhse kuhse de Changes without further notice reserved An der Kleinbahn 39 D 21423 Winsen Luhe Fax 49 4171 798 117 www kuhse...

Page 10: ...2016 07 01 doc 10 12 Alfred Kuhse GmbH Phone 49 4171 798 0 kuhse kuhse de Changes without further notice reserved An der Kleinbahn 39 D 21423 Winsen Luhe Fax 49 4171 798 117 www kuhse de 12 2 Connecti...

Page 11: ...SA_KEA 201 ERSY_EN_Ver 2016 07 01 doc 11 12 Alfred Kuhse GmbH Phone 49 4171 798 0 kuhse kuhse de Changes without further notice reserved An der Kleinbahn 39 D 21423 Winsen Luhe Fax 49 4171 798 117 www...

Page 12: ...ERSY_EN_Ver 2016 07 01 doc 12 12 Alfred Kuhse GmbH Phone 49 4171 798 0 kuhse kuhse de Changes without further notice reserved An der Kleinbahn 39 D 21423 Winsen Luhe Fax 49 4171 798 117 www kuhse de...

Reviews: