Configuration
Control box
RPB
27
Spraying flowmeter
When used for the first time, the equipment must be
calibrated.
Manual calibration:
- Note the flowmeter coefficient (1) =
A
.
- Switch to stationary spraying mode.
- Go to manual mode.
- Adjust pressure to 3 bars (44 psi).
- Place a test tube underneath the nozzle.
- Reset counters.
- Open spraying.
- Wait for 10 seconds.
- Shut-off spraying.
- Measure the volume collected in the test tube.
- Multiply the volume collected in the test tube by the
number of nozzles on the boom =
B
.
- Note the volume displayed by the control box =
C
.
- Calculate the new coefficient value =
D
:
- Press key (1) to modify parameter.
- Pres on keys (1) and (2) to adjust the value.
- Press the button (3) to confirm.
Automatic calibration:
- Press key (1) to start the automatic calibration.
- Follow screen instructions.
1
1
1
3
2
1