ORIGINAL OPERATING INSTRUCTIONS
Commissioning
March 3, 2018
28/55
7.6
Checking and setting of sensors
Hinweis
Prerequisites:
•
Spreader and carrier vehicle shall be in operation
•
Make sure that hydraulic oil pressure is sufficient
This procedure is identical for all sensors (Example: disc sensor).
Pos. No.
Explanation
10
Specification of sensor
20
Averaged value for the distance of the sensor
30
Upper value for the distance of the sensor
40
Lower value for the distance of the sensor
50
Value for the current rating at the hydraulic valve
60
Current pulses per second (disc 20, ..., 70 pulses/s / screws 40, ..., 100 pulses/s)
70
Setting current rating at hydraulic valve
Caution
Sensor too close to the sensor disc.
Danger of property damage.
•
Start measurement with sufficient safety distance with regard to the sensor disc!