ECM SYSTEM
WG1605-G-E3,WG1605-L-E3,WG1605-GL-E3, DM
1-117
DTC
1166
1171
1172
Name
Catalyst
EPR Diagnostics
EPR Diagnostics
DTC Name
Catalyst inactive on NG
EPR/CFV Regulation Pressure Higher
than Expected
EPR/CFV Regulation Pressure Lower
than Expected
J1939
SPN
3050
520260
520260
FMI
11
0
1
MIL
OFF
ON
ON
Detected Item
• Inlet pressure to DEPR is too high.
• Inlet pressure to DEPR is too low.
• Malfunctioning lock off valve,
plugged fuel filter, closed manual
valve or fuel tank out of fuel
DTC Set
Preconditions
• Engine Running
• Engine Running
• Engine Running
DTC Set
Conditions
• EGO3/4 RMS > 0.008 phi
• and EGO3/4 RMS > EGO1/2 RMS
50 %
• and EGO3/4 RMS > CL waveform
RMS 50 %
• and mass flow at ports >=
10.0 g/sec and <= CBT
CBT_ss
+/
50.0 degF
• EPR actual-commanded pressure
> 2.50 in H
2
O
• EPR actual-commanded pressure
< -2.50 in H
2
O
Period for
Judgment or
Number of
Occurrence
for Judgment
• 100 updates
• 5 sec
• 5 sec
System
Action
• CL Disable
• AL Disable KC
• AL Disable
• AL Disable
Engine
Warning Light
ON
ON
ON
KiSC issued 12, 2016 A