67
REGULAR CHECKS AND MAINTENANCE WORK
B
Cleaning Fresh Air Filter
Remove the fresh air filter, and blow air from the direction
opposite to the filter's normal air flow.
Pressure of compressed air must be under 205 kPa (2.1
kgf/cm ).
C
Cleaning the air filter
A
Normal use
Blow air from the opposite direction to the filter's
normal air flow.
Pressure of compressed air must be under 205 kPa
(2.1 kgf/cm ).
A
Do not hit the filter. If the filter becomes deformed, dust
may enter into the air-conditioner, which may cause
damage and malfunction.
A
Do not use gasoline, thinner or similar chemicals to
clean the filter as damage to the filter may occur.
It may also cause an unpleasant odor in the Cab when
the system is used next.
B
Cleaning Recirculation Air Filter
To avoid personal injury or death:
A
When removing and attaching the filter, apply
parking brake, stop the engine and remove the
key.
Remove the thumbscrews and pull out filter.
A
Attach the filter and cover as the illustration above.
C
Cleaning the air filter
A
Normal use
Blow air from the opposite direction to the filter's
normal air flow.
Pressure of compressed air must be under 205 kPa
(2.1 kgf/cm ).
(1) Fresh air filter
(A) "AIR CONDITIONER AIRFLOW"
(1) Cover
(2) Thumbscrew
(1) Recirculation air filter
(2) Cover
(3) Thumbscrew