The foot flange is generally supplied ready for assembly.
Components of Foot Flange
Component Quantity
Designation
1 1
foot flange
PTFL or PTFS
picture 1: foot flange PTFL
picture 2: foot flange PTFS
Assembly Bellhousing with Foot Flange
•
The bellhousing is hung into the foot flange with its external centering (ØB3).
picture 3: combination bellhousing-foot flange PTFL
picture 4: combination bellhousing-foot flange PTFS
•
Put the cap screws according to DIN 912 into the through holes of the bellhousing and the foot
flange and screw both parts with a nut according to DIN 985 and a disk according to DIN 125 or
comparable. You can find the screw tightening torques in table 1.
Table 1:
cap screw DIN 912
1
M8 M10 M12 M16 M20
tightening torque
2
25 Nm
49 Nm
86 Nm
210 Nm
410 Nm
1
min. property class 8.8
2
tightening torques of the property class 8.8
A T T E N T I O N !
The screws must be generally used with Loctite, Omnifit 230M or comparable
adhesives for securing.
!
C A U T I O N !
In order to achieve the full loading capacity of the foot flanges, all existing
fastening bores must be screwed with the bellhousing.
Further Information
Assembly of the bellhousing-foot flange combination with the electric motor and pump see
KTR-N 41010 „Mounting instructions bellhousing“.