9
SHOCK ABSORBER, SWINGARM
54
200269-10
–
When the pressure gauge reaches the required value, turn control lever
Damper
4
to
Vacuum
.
Guideline
3 bar
The pressure gauge drops to the required value.
0 bar
–
When the pressure gauge reaches the required value, activate the
On/Off
switch.
Guideline
0 bar
The vacuum pump is switched off.
201768-10
–
Slide O-ring
B
to the end of the special tool by the specified value (distance
A
minus specified value).
Guideline
10 mm
Depth micrometer (T107S) (
–
Slide the floating piston into the reservoir to the shortened position using the spe-
cial tool.
Info
The floating piston must be positioned at exactly this point when the rod
is fully extended; otherwise, damage will occur during compression of the
shock absorber.
–
Remove the special tool.
201769-10
–
Remove adapter
1
from connector
2
of the vacuum pump.
Info
Hold the damper so that the filling port is at the highest point.
–
Remove the adapter.
–
Mount and tighten screw
9
.
Guideline
Screw, filling port
M10x1
14 Nm
(10.3 lbf ft)
9.24
Filling the damper with nitrogen
201764-10
–
Screw in screw
1
by approx. 2 turns but do not tighten.
Info
The piston rod is fully extended.
201765-10
–
Fix the special tool in the vise.
Nitrogen filling tool (T170S1) (
–
Connect the special tool to the pressure regulator of the filling cylinder.
Filling gas - nitrogen
–
Adjust the pressure regulator.
Guideline
Gas pressure
10 bar (145 psi)
–
Position the damper in the special tool.
The hexagonal part of tap handle
A
engages in the hexagon socket of the fill-
ing port screw.