3 WORK
12
Guideline
The charging current, charging voltage, and charging time
must not be exceeded.
Recharge the 12-V battery
regularly when the motorcy-
cle is not being used
3 months
Finishing work
–
Install the 12-V battery. (
–
Mount the seat. (
–
Set the time and date.
3.5
Removing the 12-V battery
Warning
Risk of injury
Battery acid and battery gases cause serious chemical burns.
–
Keep 12 V batteries out of the reach of children.
–
Wear suitable protective clothing and safety glasses.
–
Avoid contact with battery acid and battery gases.
–
Keep sparks or open flames away from the 12 V battery.
–
Only charge 12 V batteries in well-ventilated rooms.
–
Rinse the affected area immediately with plenty of water in the event of contact with the skin.
–
Rinse eyes with water for at least 15 minutes and consult a doctor immediately if battery acid and
battery gases get into the eyes.
Caution
Danger of accidents
Electronic components and safety devices will be damaged if the 12-V battery is dis-
charged or missing.
–
Never operate the vehicle with a discharged 12-V battery or without a 12-V battery.
Preparatory work
–
Switch off ignition - to do this briefly press the Race-on but-
ton
(maximum of 1 second) with the ignition switched on.
–
Remove the seat. (
S02274-10
Main work
–
Pull locking mechanism
1
in the direction of the arrow.
–
Fold open cover
2
.