6
FORK, TRIPLE CLAMP
43
200684-10
–
Measure the outside diameter at multiple locations of the inner tube.
Outside diameter of inner tube
47.975… 48.005 mm (1.88878…
1.88996 in)
» If the measured value is smaller than the specified value:
–
Change the inner tube.
200685-10
–
Measure the run-out of the inner tube.
Inner tube run-out
≤
0.20 mm (
≤
0.0079 in)
» If the measured value is larger than the specified value:
–
Change the inner tube.
200632-10
–
Measure the inside diameter at multiple locations of the outer tube.
Inside diameter of outer tube
≤
49.20 mm (
≤
1.937 in)
» If the measured value is larger than the specified value:
–
Change the outer tube.
–
Check the outer tube for damage.
» If there is damage:
–
Change the outer tube.
200665-10
–
Check the surface of the sliding bushings.
» If the bronze-colored layer
A
under sliding layer
B
is visible or the surface is
rough:
–
Change the sliding bushings.
200666-10
–
Check the spring length.
Guideline
Spring length with preload spacer(s)
470 mm (18.5 in)
» If the measured value is larger than the specified value:
–
Reduce the thickness of the preload spacers.
» If the measured value is smaller than the specified value:
–
Increase the thickness of the preload spacers.
6.2.19
Assembling the seal ring retainer
Info
The steps are identical for both fork legs.