15
WIRING HARNESS, BATTERY
101
15.1
Plug-in connection, ignition timing map
B00029-10
Plug-in connection
1
is located in front of the fuel tank on the left side of the frame.
Possible states
• Soft
–
The plug-in connection is disconnected to achieve better rideability.
• Performance
–
The plug-in connection is connected to achieve higher
performance.
15.2
Removing the main fuse
Preparatory work
–
Switch off all power consumers and switch off the engine.
–
Remove the air filter box lid. (
400270-10
Main work
–
Remove the protection cover
1
.
Info
The main fuse
2
is located in the starter relay
3
under the filter box cover.
–
Remove main fuse
2
.
15.3
Installing the main fuse
Warning
Fire hazard
The electrical system can be overloaded if the wrong fuses are used.
–
Use only fuses with the prescribed amperage. Never by-pass or repair fuses.
400273-10
–
Insert the main fuse.
Fuse (58011109110) (
Info
A reserve fuse
1
is located in the starter relay.
Replace a burned-out fuse
2
only by an equivalent fuse.
–
Replace the protection cover.
–
Install the air filter box lid. (
15.4
Recharging the battery
Warning
Risk of injury
Battery acid and battery gases cause serious chemical burns.
–
Keep batteries out of the reach of children.
–
Wear suitable protective clothing and goggles.
–
Avoid contact with battery acid and battery gases.
–
Keep sparks and open flames away from the battery. Only charge in well-ventilated rooms.
–
In the event of skin contact, rinse with large amounts of water. If battery acid gets in the eyes, rinse with water for at least
15 minutes and contact a physician.
Warning
Environmental hazard
The battery contains elements that are harmful to the environment.
–
Do not discard batteries with the household waste. Dispose of faulty batteries in an environmentally compatible manner.
Give the battery to your authorized KTM dealer or dispose of it at a collection point for used batteries.