-6-
Note:
1. For connecting to early 1000BASE-X devices which do not provide
auto negotiation capability, you might need to set the SW to NON-
AUTO position to prevent unexpected link failure occurrence.
2. In most of the cases, setting AUTO would make the link worked.
3. When installing two of these converters on both ends of a fiber
connection, set the switch to NON-AUTO (forced full duplex mode)
to achieve the best performance.
Model
Fiber
Wavelength
Output power
Input Sensitivity
210TF-SXC
SX
850nm
-9.5 ~ -4 dBm
-12.5dBm max.
210TF-SXC-O
SX
850nm
-9.5 ~ -4 dBm
-18dBm max.
210TF-LXC
LX
1310nm
-9.5 ~ -3 dBm
-14.4dBm min.
210TF-LXC-O
LX
1310nm
-9 ~ -3 dBm
-21dBm min.
210TF-LXC30-O
LX
1310nm
-5 ~ 0 dBm
-24dBm min.
210TF-LXC40 LX
1550nm DFB -5 ~ 0 dBm
-24 dBm max.
210TF-LXC80 LX
1550nm DFB -2 ~ 3 dBm
-24 dBm max.
Model
Fiber Used
Cable Length
210TF-SXC
MMF 62.5/125
220 meters
MMF 50/125
500 meters
210TF-SXC-O
MMF 62.5/125
300 meters
MMF 50/125
500 meters
210TF-LXC
MMF 62.5/125
550 meters
MMF 50/125
550 meters
MM: Multimode
SMF 9/125
10Km
SM: Single mode
210TF-LXC-O
SMF 9/125
10Km
210TF-LXC30-O
SMF 9/125
30Km
210TF-LXC40 SMF 9/125
40 ~ 50Km
210TF-LXC80 SMF 9/125
80Km