background image

M 1 6 7 - E 6 5 0 U - 0 0 1

HIGH PERFORMANCE

CCTV CAMERA

O P E R AT I O N   M A N U A L

Thank you for choosing our high quality camera.

Before attempting to connect or operate, please read and 

follow these instructions.

NAME AND FUNCTION

• LENS CONNECTION

Lenses are sold separatele. Lenses such as an auto iris lens,

CS-Mount lens and C-Mount lens can be used.

NOTE

• Please keep the lens clean.

• Any foreign objects and fingermarks on the lens can cause

 inferior image quality in low light level conditions.

When using an auto iris lens

1.Please peel off about 8mm of the 

   outer skin of the auto iris lens cable.

2. Please  peel off about 2mm of the 

    outer skin of the insulated conductor

    inside the lens cable.

3. Please remove the cover of the auto iris lens connection plug and solder

    the lens cable ti the connector pin in the plug.

*PIN ASSIGNMENT OF THE LENS CONNECTOR

 

Signal for DC + iris lens

Pin 1: DAMP-

Pin 2: DAMP+

Pin 3: DRV+

Pin 4: DRV-(GND)

Signal for Video + iris lens

Pin 1: Power source: +9 DC,50mA MAX

Pin 2: N.C(Not used)

Pin 3: Video Signal:0.7Vp-p/10K ohms.

Pin 4: Shield, ground

4. Please replace the auto iris lens connection plug cover and take off the

    CCD protection cap and than attach the auto iris lens to the camera by   

    screwing it in clockwise.

Back Focus Procedure

Step 1 - Remove Lens Cover.

Step 2 - If using a C-Mount lenses it can be applied 

             to the camera at this time.

Step 3 - Most current lenses are CS-Mount and 

             require removal of the C/CS ring.

Step 4 - To remove the C/CS ring loosen but do not 

              remove completely the two set screws and 

              than remove the C/CS ring.

Step 5 - Screw on the CS-Mount lens until a good 

             picture is obtained and tighten the set screws.

Step 6 - Use the focus ring on the lens to obtain 

             a finer focusing

NOTE

- if a C-Mount lens was applied and focus could not be obtained, please try the following :

  • Ensure that the lens is in face a C-Mount and not a CS-Mount.

  •Check the focus adjust on the lens.

  • if need be loosen the set screws and adjust the position of the lens

    and C/CS ring as one unit until a good focus is obtained.  

5. Please insert the connection plug that is connected to the auto iris lens cable into the 

auto lens connector, which is located on the back of the camera

* As the connecting method varies with instruments, refer to the

  manual supplied with the instrument.

* Only connect the cable when the power is turned off.

* Set the 75Ω / Hi-Z selection switch as shown below if you have an intermediate device.

This device complies with Part 15 of the FCC

Rules. Operation is subject to the following

two conditions;

1. This device may not cause harmful interference.

2. This device must accept any interference received,  including 

    interference that may cause undesired operation.

Any changes or modifications in construction of this devies which are not 

expressly  approved  by  the  party  responsible  for  compliance  could  void  the 
user's authority to operate the equipment.

Caution -

 CAUTION 

1. A regulated DC12V 300mA power supply is recommended for use with 

this camera for the best picture and the most stable operation. 

An unregulated power supply can cause damage to the camera.
When unregulated power supply is applied, product warranty will be
out of subject.

2. It is recommended that the camera is used with a monitor that has a 

CCTV quality 75 video impedance level. If your monitor is switched to 

high impedance then please adjust accordingly.
3. Do not attempt to disassemble the camera to gain access to the 
internal componets. Refer servicing to your dealer.

4. Never face the camera towards the sun or any bright or reflective light, 

which may cause smear on the picture and possible damage to the CCD.

5. Do not remove the serial sticker for the warranty service.

This equipment has been tested and found to comply with the limits for a 

Class A digital device, pursuant to part 15 of the FCC Rules. These limits are 

designed to provide reasonable protection against harmful interference when 

the  equipment  is  operated  in  a  commercial  environment.  This  equipment 
generates, uses, and can radiate radio frequency energy and, if not installed 

and used in accordance with the instruction manual, may cause harmful 

interference  to  radio  communications.  Operation  of  this  equipment  in  a 

residential area is likely to cause harmful interference in which case the user 

will be required to correct the interference at his own expense.”  

Note -

This is a class A product. In a domestic environment this product may cause 

radio interference in which case the user may be required to take adequate 

measures.

WARNING -

CAUTIONS

CAUTIONS

Correct Disposal of This Product

(Waste Electrical & Electronic Equipment)

(Applicable in the European Union and other European 

countries with separate collection systems)

This marking shown on the product or its literature, indicate that 

it should not be disposed with other household wastes at the end 

of its working life. To prevent possible harm to the environment or 

human health from uncontrolled waste disposal, please separate 

this from other types of wastes and recycle it responsibly to 

promote the sustainable reuse of material resources.

This product should not be mixed with other commercial wastes 

purchased this product, or their local government office, for details 

of where and how they can take item for environmentally safe 

recycling.

Business users should contact their supplier and check the terms 

and conditions of the purchase contract.

Household users should contact either the retailer where they for 

disposal.

CAUTION

RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION : TO REDUCE THE RISK OF ELECTRIC SHOCK, DO 

NOT REMOVE COVER(OR BACK). NO USER. SERVICING TO 
QUALIFED SERVICE PERSONNEL.

This symbol is intended to alert the user to the presence 

of uninsulated "dangerous voltage" within the product's 

enclosure that may be of sufficient mangnitude to constitute 

a risk of electric shock to persons.

This symbol is intended to alert the user to the presence of 

important operating and maintenance(servicing) instruction in 

the literature accompanying the appliance.

COMPONENTS

FRONT

BACK

CS-Mount

C-Mount

High Performance
DSP Color Camera

Auto Iris Lens
Connection Plug

C-mount Adaptor Ring

Spare Screw (Machine 2x2) - 2ea 

Operation Manual

Lens Cover

Lens Cover

C/CS RING

AUTO

IRIS

OSD

CONTROL

INSTALLATION

• MONITOR CONNECTION

BNC FEMALE

VIDEO

DC12V REGULATED

POWER SUPPLY

VIDEO IN

■ 

MENU BUTTON

   ▲ 

UP BUTTON

   ▼ 

DOWON BUTTON

   ◀ 

LEFT BUTTON

   ▶ 

RIGHT BUTTON

. Auto IRIS Jack

CS-MOUNT ADAPTOR RING

Set Screw(Left Side)

Reviews: