background image

 

 



Allrightsreserved.
Theinformationinthisdocumentissubjecttochangewithoutnotice.






















Publishstatement

ThankyouforpurchasingthisseriesUPS.
ThisseriesUPSisanintelligent,singlephaseinsinglephaseout,highfrequency
onlineUPSdesignedbyourR&Dteamwhoiswithyearsofdesigningexperienceson
UPS.Withexcellentelectricalperformance,perfectintelligentmonitoringand
networkfunctions,smartappearance,complyingwithEMCandsafetystandards,The
UPSmeetstheworld’sadvancedlevel.
Readthismanualcarefullybeforeinstallation
Thismanualprovidestechnicalsupporttotheoperatoroftheequipment. 


Summary of Contents for UDC9101H One

Page 1: ...out high frequency online UPS designed by our R D team who is with years of designing experiences on UPS With excellent electrical performance perfect intelligent monitoring and network functions smar...

Page 2: ...d in this guide 5 2 Installation and setup 5 2 1 Unpack checking 5 2 2 Real panel view 6 2 3 Setup the UPS 7 2 4 UPS start up and turn off 9 3 Operations 13 3 1 Button operation 13 3 2 LCD display 13...

Page 3: ...y occur if the UPS system is moved directly from cold to warm environment The UPS system must be absolutely dry before being installed Please allow at least two hours for the UPS system to acclimate t...

Page 4: ...ed to the battery and electrically live and dangerous Before carrying out any kind of service and or maintenance disconnect the batteries and verify that no current is present and no hazardous voltage...

Page 5: ...the package is damaged Please keep the original package in a safe place for future use 2 1 Unpack checking Don t lean the UPS when moving it out from the packaging Check the appearance to see if the...

Page 6: ...6 2 2 Real panel view 1KVA S 1KVA H 2KVA S 2KVA H 3KVA H...

Page 7: ...ommunication port 7 SNMP intelligent slot option 8 Output receptacles 9 Battery Terminal 10 Output Terminal 2 3 Setup the UPS Step 1 UPS input connection Plug the UPS into a two pole three wire ground...

Page 8: ...u can schedule UPS shutdown start up and monitor UPS status through PC The UPS is equipped with intelligent slot perfect for either SNMP or Relay card When installing either SNMP or Relay card in the...

Page 9: ...hold the ON key for more than half a second to start UPS b The operation of the UPS in the process of start is almost the same as that when mains power is in After finishing the self test the correspo...

Page 10: ...UPS has an active alarm or fault Yellow The UPS is in Bypass mode On The UPS is operating normally on bypass during High Efficiency operation Yellow On The UPS is in Battery mode Green On The UPS is...

Page 11: ...selection in setting mode or enter setting mode LCD Display Icons Icon Function description Input Source Information Indicates the AC input Indicate input voltage input frequency PV voltage battery vo...

Page 12: ...urns 25 49 Bottom bar will be on and the other three bars will flash in turns 50 74 Bottom two bar will be on and the other two bars will flash in turns 75 100 Bottom three bar will be on and thetop b...

Page 13: ...d hold this button it will switch to normal mode OFF ESC Button Turn off the UPS Press and hold this button at least 2 seconds to turn off the UPS in battery mode UPS will be in standby mode under pow...

Page 14: ...14 Item Interface Description Content Displayed 01 Input voltage Output voltage 02 Battery voltage Battery capacity 03 Input frequency Output frequency 04 Load 05 Environment Temperature...

Page 15: ...d of UPS working mode The setting will take effect under certain condition Below table describes how to set the UPS The setting function is controlled by 4buttons Up Down ON Enter OFF ESC Up OFF Down...

Page 16: ...the next setting 03 Frequency setting Press Enter button to change the setting 50 or 60Hz Press UP button to select the previous setting Press DOWN button to select the next setting 04 Battery capaci...

Page 17: ...220Vac Press UP button to select the previous setting Press DOWN button to select the next setting 08 Mute setting Press Enter button to change the setting ON or OFF Press UP button to select the pre...

Page 18: ...Beep continuously Fault LED lit 19 UPS Inside Over Temperature Twice per second Fault LED lit 20 Heatsink Over Temperature Twice per second Fault LED lit 26 Battery over voltage Once per second Fault...

Page 19: ...ontact your dealer Alarm code is shown as 34 and battery led blinking Battery voltage is too low or the charger is fault Contact your dealer Alarm code is shown as 32 and INV or BYPASS led blinking UP...

Page 20: ...20 Trouble Shooting Chart...

Page 21: ...thecard Carefully insert the SNMP card and lock the screws The slot called SNMP supports the MEGAtec protocol We advise that Net AgentII 3 port is also a tool to remotely monitorand manage any UPS sys...

Page 22: ...nal board to facilitate the effective monitoring of the real timestatus of UPS and timely feedback the statusto monitor when abnormal situation occurs suchas UPS failure mains interruption UPS bypassa...

Page 23: ...oltage point 230 264 setting the high voltage point in LCD from 230Vac to 264Vac Default 264Vac Bypass low voltage point 170 220 setting the low voltage point in LCD from 170Vac to 220Vac Default 170V...

Page 24: ...bypass after 5 seconds when the utility is normal 130 UPS transfer to bypass immediately when the utility is normal Short Circuit Hold Whole System Overheat Line Mode Switch to Bypass Backup Mode Shu...