OPERATING DISTANCES

On the mounting surface (not ferromagnetic), for all configurations and the axes of operation (x - y - z) based 
on how the device is installed.

Vertical installation of the detector
Axis x                                    Closed contact 20 mm       Open Contact 30 mm
Axis y magnet at 10 mm    Closed contact 20 mm        Open Contact 30 mm
Axis z magnet at 10 mm    Closed contact 20 mm        Open Contact 25 mm
   

In order to maintain the conformity with the norms listed on last page, please insert a screw as shown in 
figure.

BATTERY INCLUDED

Note

: temperatures below +5 °C can cause the poli to report a false low battery indication. 

Operation below +5 °C will reduce the battery life significantly.

Caution!

 Observe the correct polarity when installing battery. Use only Panasonic Lithium CR-123A 

batteries for replacement.

Warning!

 Battery may explode if the battery is replaced by an incorrect type or if mistreated. Do not 

recharge, disassemble or dispose of in fire. Dispose of used batteries according to the instructions.

QUANTITY DATA

lares 4.0 models

wls 96

16

40

40 wls

140 wls

644 wls

Maximum number of sensors 
(poli, nanus, unum, nebula, 
velum)

32

16

40

40

64

64