4 Valve Description
25 of 72
0570.81/22-EN
4.6.2 STAAL 100 AKK/AKKS
Fig. 12:
STAAL 100 AKK/
AKKS
4.6.2.1 General description
▪
Swing check valve with bolted cover
Valve for preventing backflow in industrial plants, power stations, process
engineering and shipbuilding.
4.6.2.2 Design details
Design
▪
Body of forged or welded steel construction
▪
Bolted cover
▪
Internally mounted hinge pin
Variants
▪
Extended hinge pin from DN 300 (for lever and weight)
▪
Other flange designs
▪
Other butt weld end versions
▪
Drain branch
▪
Inspections to technical codes such as TRD/TRB/AD2000 – German Steam Boiler /
Pressure Vessel Regulations – or to customer specification
▪
DN 400 and above: on request
4.6.2.3 Function
Design
Swing check valves comprise forged body 100 with hard-faced seating faces. Fluid
flow is shut off by hard-faced valve disc 746, which is flexibly mounted on hanger
arm 570. This connection is secured by means of a nut and a safety pin.
Sealing
Body 100 is bolted to cover 161 using studs 902.1 and sealed to atmosphere by joint
ring 411.1. The disc assembly is pivot-mounted on hinge 230 welded to cover 161 or
on hinge pin 210 mounted in the body.