8 Servicing/Maintenance
66 of 76
EtaLine Pro
1168.87/01-EN
8.5.4 Installing the back pull-out unit
WARNING
Back pull-out unit tilting
Risk of squashing hands and feet!
▷
Suspend or support the back pull-out unit at the pump end.
ü
The notes and steps stated in (
Section 8.5.3, Page 65) have been observed/carried out.
ü
Any damaged or worn components have been replaced with original spare parts.
ü
The sealing surfaces have been cleaned.
1. Suspend or support the back pull-out unit to prevent it from tipping over.
2. Fit new O-ring 412 on casing cover 161.
3. Insert the back pull-out unit into volute casing 102.
4. Tighten hexagon socket head cap screws 914 with connection discs 81-43 on
motor flange 801. Observe the tightening torques. (
8.6 Tightening torques
Table 33:
Tightening torques for bolted/screwed connections at the pump
Part No.
Quantity
Thread
Tightening torque
[Nm]
741
1
G1/4 A
35,0
900.01
4
M4
2,6
900.02
4
M4
1,0
900.03
4
M4
2,6
900.04
2
4
1,0
900.05
2
4
1,0
903.01/.02
2
G1/4 A
55
914
4
M8
25,0
920
1
M8
29
8.7 Spare parts stock
8.7.1 Ordering spare parts
Always quote the following data when ordering replacement or spare parts:
▪
Type series
▪
Size
▪
Material variant
▪
Seal code
▪
Material number
▪
Series code
Refer to the name plate for all data.
Also specify the following data:
▪
Part number and description
▪
Quantity of spare parts
▪
Shipping address
▪