4 Valve Description
14 of 38
ECOLINE GT 40
7367.8/06-EN
Fluid groups
In accordance with Article 13 Para. 1 of the European Pressure Equipment Directive
(PED) 2014/68/EU, Group 1 comprises all fluids posing physical or health hazards, e.g.
fluids defined as
▪
Explosive
▪
Extremely flammable
▪
Highly flammable
▪
Very toxic
▪
Toxic
▪
Oxidising
Group 2 comprises all other fluids not referred to in Group 1.
4.4 Design details
Design
▪
Bolted bonnet
▪
Non-rotating stem with external screw
▪
Back seat
▪
Flexible wedge
▪
Yoke head suitable for mounting electric actuators (DIN ISO 5210)
Variants
▪
Stem protecting tube
▪
Stem protecting tube with position indicator
▪
Stem protecting tube with position switch
▪
Bypass
▪
Installation kit for electric actuators to EN ISO 5210 Type A
▪
Spur gear
▪
Bevel gear
▪
Electric actuators
▪
Body seating surfaces made of wear and corrosion resistant Stellite.
▪
Other flange designs
▪
Other butt weld end versions
▪
Version in compliance with TA-Luft (German Clean Air Act) to VDI 2440 for
temperatures up to 400 °C
4.5 Information on the mechanical components
4.5.1 Moving parts
The valve/actuator combination comprises moving parts which are not fully enclosed.
Depending on the type and design, these include the following:
▪
Stem
▪
Limit switches
▪
Coupling
▪
Other force-transmitting equipment
Depending on the actuator type and design, further moving parts may be present,
e.g. emergency handwheels turning along with the actuator.