background image

BOA

R

-R

3

Dimensions

Angle pattern

Straight-way pattern

h

1

l

1

d

3

k

D

C

h

2

l

2

l

2

d

3

k D

C

Dimensions

(mm)

Weight

(kg) approx.

Straight-way

pattern

Angle

pattern

PN

DN

I

1

I

2

h

1

h

2

D

ø

k

n x d

3

C

kg

kg

6

1

)

15

130

--

50

--

95

55

4 x 11

14

2.3

--

JL1040

20

150

--

60

--

105

65

4 x 11

16

3.5

--

25

160

--

65

--

115

75

4 x 11

16

4.0

--

32

180

--

85

--

140

90

4 x 14

18

6.9

--

40

200

--

90

--

150

100

4 x 14

18

8.0

--

50

230

--

95

--

165

110

4 x 14

20

10.5

--

65

290

--

120

--

185

130

4 x 14

20

16.8

--

80

310

--

130

--

200

150

4 x 19

22

22.0

--

100

350

--

155

--

220

170

4 x 19

24

32.5

--

125

400

--

175

--

250

200

8 x 19

26

52.0

--

150

480

--

195

--

285

225

8 x 19

26

72.0

--

200

600

--

245

--

340

280

8 x 19

30

123.0

--

16

15

130

90

50

25

95

65

4 x 14

14

2.3

2.2

JL1040

20

150

95

60

35

105

75

4 x 14

16

3.5

3.2

JS1025

25

160

100

65

35

115

85

4 x 14

16

4.0

4.1

32

180

105

85

50

140

100

4 x 19

18

6.9

6.9

40

200

115

90

50

150

110

4 x 19

18

8.0

8.0

50

230

125

95

60

165

125

4 x 19

20

10.5

10.2

65

290

145

120

70

185

145

4 x 19

20

16.8

16.1

80

310

155

130

75

200

160

8 x 19

22

22.0

19.5

100

350

175

155

95

220

180

8 x 19

24

32.5

30.3

125

400

200

175

105

250

210

8 x 19

26

52.0

45

150

480

225

195

110

285

240

8 x 23

26

72.0

64.5

200

600

275

245

140

340

295

12 x 23

30

123.0

108

250

730

325

295

150

400

355

12 x 28

32

200.0

170

300

850

300

335

185

460

410

12 x 28

32

310.0

262

350

2

)

980

--

335

--

520

470

16 x 28

36

357.0

--

1

) Pattern of drilled holes to PN 6 (dimensions k and nxd); however, flanges dimensioned to PN 16 (dimensions D and b). Please take this into

account when selecting the flange connecting bolts.

2

) DN 350 only in EN-GJS-400-18-LT

Installation instructions

Observe direction of flow and integral direction arrow.

For opening, a minimum pressure is required. If this pressure

is not attained, the installed closing spring can be removed.

Valves without a closing spring can only be installed upright in

horizontal pipelines.

Minimum opening pressures

(bar)

DN

15-50

65-150

200-350

With spring

0.250

0.200

0.150

Without spring

0.025

0.016

0.022

Connection dimensions -- Standards:

Flanges:

DIN EN 1092--2, type of flange 21 -- JL1040

type of flange 21-2 -- JS1025

Raised faces: DIN EN 1092--2, type B

Face-to-face dimension:
Straight-way pattern: EN 558/1

ISO 5752/1

Angle pattern:

EN 558/8

ISO 5752/8

Reviews: