background image

BOA -R

Type series booklet
7117.1/13-10

®

Maintenance-free

metallic-seat

flanged

non-return valves

DN 15-350

PN 6, 16

Application

Warm-water heating systems

Hot-water heating systems

Heat-transfer installation

Pressure vessel equipment to TRB 801 nr. 45

1)

Boiler installations to TRD 108/110

1)

Other fluids on request

1

) Please contact KSB for limitations imposed by the applicable

technical codes.

Operating data

Temperature range:

--10 up to +300

°

C for EN-GJL-250 *)

--10 up to +350

°

C for EN-GJS-400-18-LT *)

--30

°

C for EN-GJS-400-18-LT **) with bolts for low-tempera-

ture service

Pressure range:

Straight way pattern up to

p = 6 or 16 bar

Angle pattern up to

p = 16 bar

Materials

Body:

Straight-way pattern:

Cast iron with flake graphite EN-GJL-250

Cast iron with nodular graphite EN-GJS-400-18-LT

Angle pattern:

Cast iron with flake graphite EN-GJL-250

For further details, see table of materials

Standard design

Straight-way or angle pattern with horizontal seat

With spring-loaded check cone

Free from asbestos, CFC, PCB

Exterior finish: blue similar to RAL 5002

Variants

Oil and grease-free design

Other flange design

Additional information

Operating instructions: 0570.8

Type-tested to the specifications of Germanischer Lloyd

On all enquiries/orders please specify

Non-return valve

1. BOA

R

-R according to type series booklet 7117.1

2. PN 6 or 16

3. EN-GJL-250, JL 1040 or EN-GJS-400-18-LT, JS 1025

4. Straight-way and angle pattern

(angle pattern only EN-GJL-250)

5. DN 15-350 (DN 350 only in EN-GJS-400-18-LT)

6. Variant

*) For operating temperatures > 200

°

C and uninsulated

valves please use the valve variant with high--temperature

resistant paint.

The valves meet the safety requirements of the Pressure

Equipment Directive 97/23/EC (PED) of annex I for fluids of

the groups 1 and 2.

The valves do not have a potential internal source of ignition

and can be used in potentially explosive atmospheres,

group II, category 2 (zones 1+21) and category 3 (zones

2+22) according to ATEX 94/9/EC.

PED 97/23/EC

Reviews: