KSB BACnet MS/TP Supplementary Operating Manual Download Page 1

BACnet MS/TP Gateway

For Calio

Supplementary Operating

Manual

Summary of Contents for BACnet MS/TP

Page 1: ...BACnet MS TP Gateway For Calio Supplementary Operating Manual...

Page 2: ...contents provided herein must neither be distributed copied reproduced edited or processed for any other purpose nor otherwise transmitted published or made available to a third party without the man...

Page 3: ...3 Description 6 3 1 Compatibility 6 3 2 General description 6 3 3 Commissioning 6 3 3 1 Setting jumpers 8 3 3 2 DIL switch 8 3 3 3 Back up battery 8 3 3 4 Error code 9 3 3 5 Technical data 9 4 Related...

Page 4: ...information contained in the installation operating manual must be observed Table 1 Relevant operating manuals Type series Reference number of the operating installation manual Calio 1157 82 Manufactu...

Page 5: ...ed for a maximum of 12 months Table 2 Ambient conditions for storage Ambient condition Value Relative humidity 85 max non condensing Ambient temperature 10 C to 70 C 1 Store the device in dry conditio...

Page 6: ...umber Master node address 1 MS TP baud rate 38400 The default device ID of the gateway used to identify the device on the BACnet network is created based on the sum total of 247000 fixed value and the...

Page 7: ...voltage Danger to life Only remove the printed circuit board when de energised 1 2 3 5 4 Fig 2 Removed electronics 1 MS TP bus terminator jumper must be terminated at the last station subscriber 2 Mo...

Page 8: ...0 0 4 0 0 0 1 0 0 0 8 0 0 1 0 0 0 0 16 0 1 0 0 0 0 0 32 1 0 0 0 0 0 0 64 The master node address can be set from 1 to 127 using the DIP switches It may be necessary to activate several switches to obt...

Page 9: ...mA at 24 V DC Enclosure IP20 Housing design DIN rail assembly Weight Approx 0 1 kg Dimensions W x H x D 18 x 90 x 115 mm Table 5 Object list Type Instance Object name Value Read Write Description AI 1...

Page 10: ...Error R FP 19200 E 8 1 B 1000 1000 PRG 1 P BASIC Program Running Halted R W KSB Calio adaption c V20150805 HHO uha MV 1 Calio_OpMode Eco Mode Const Pr Propor Pr Boost R W Selecting the operating mode...

Page 11: ...tion or fault 5 Service terminal terminals 6 Power supply 9 30 V DC A B GND A B G Calio Tx Rx GND Modbus RS485 NC 0 30VDC 9 30VDC B A GND MS TP NO COM NC R O Uin 0 Run External 0 10 V 0 10V COM Alert...

Page 12: ...oduct BACnet MS TP gateway Serial number range 2018w01 to 2019w52 is in conformity with the provisions of the following Directives as amended from time to time Electromagnetic Compatibility Directive...