6 Operation
23 of 32
AmaSlide
2553.870/01-EN
6.3 Moving the maintenance aid into operating position
901.62
Fig. 17:
Servicing position
ü
The pump set is in servicing position.
1. Undo and remove hexagon head bolts 901.62 at the motor end.
2. Guide the back pull-out unit including motor along the guide rails until it abuts
the pump casing.
The force required to move the back pull-out unit depends on the motor
weight.
920.01
901.62
920.01
Fig. 18:
Operating position
3. Tighten nuts 920.01 at the pump set.
4. Fit hexagon head bolts 901.62 in their new position in front of the pump-end
roller and tighten them.
ð
The pump set is in operating position and can be returned to service.