Critical speed
Increased vibrations!
Damage to mechanical seals and bearings!
▷
Install a swing check valve in longer riser pipes to prevent the pump from
excessive running in reverse.
When fitting a swing check valve, make sure that the unit can still be vented
properly.
F
x
F
z
F
y
M
y
M
z
M
x
Fig. 6:
Permissible flange
loads
Table 10:
Permissible flange loads
Nominal flange
diameter
Forces [N]
Moments [Nm]
F
y
F
z
F
x
∑
F
M
y
M
z
M
x
∑
M
50-65
1350
1650
1500
2600
1000
1150
1400
2050
80
2050
2500
2250
3950
1150
1300
1600
2350
100
2700
3350
3000
5250
1250
1450
1750
2600
5.3.1.3 Fitting the guide wire arrangement
The pump set is guided into the sump or tank along two parallel, tightly stretched
guide wires made of stainless steel. It attaches itself automatically to the duckfoot
bend which has been fitted to the floor.
NOTE
Should site conditions/piping layout, etc. require the wire to run off the vertical, do
not exceed a maximum angle of 5° to ensure reliable fitting and guiding of the
pump set.
Fitting the mounting bracket
Fig. 7:
Fitting the mounting
bracket
1.
Fasten mounting bracket 894 to the edge of the tank/sump opening with steel
anchor bolts 90-3.37 and tighten the anchor bolts to a tightening torque of
10 Nm.
2.
Feed clamping pieces 571 through the holes of suspension bracket 572 and
fasten with nuts 920.37.
3.
Fasten fully threaded stud 904 with the pre-assembled clamping arrangement to
the mounting bracket with nut 920.36.
Do not tighten nut 920.36 too much in order to allow sufficient play for
subsequently tensioning the guide wire.