6 Commissioning/Start-up/Shutdown
40 of 84
Amarex N
2563.84/08-EN
Fig. 17:
Minimum fluid level
NOTE
For pump sets with cutters we recommend continuing pump operation for about 10
seconds after the minimum suction level has been reached (see dimension RS in the
outline drawing).
Operation with a dropping fluid level up to dimension R1 (see outline drawing) is
permissible. Please note that during that time frequent starting and stopping of the
pump set must be avoided.
6.2.4.3 Density of the fluid handled
The power input of the pump set will change in proportion to the density of the fluid
handled.
CAUTION
Impermissibly high density of the fluid handled
Motor overload!
▷
Observe the information about fluid density in the data sheet.
▷
Make sure the motor has sufficient power reserves.
6.3 Shutdown/storage/preservation
6.3.1 Measures to be taken for shutdown
DANGER
Electrical connection work by unqualified personnel
Danger of death from electric shock!
▷
Always have any work on the connection to the power supply performed by a
trained electrician.
▷
Observe regulation EN 60079.
WARNING
Unintentional starting of the pump set
Risk of injury by moving components and shock currents!
▷
Ensure that the pump set cannot be started unintentionally.
▷
Always make sure the electrical connections are disconnected before carrying
out work on the pump set.