The drive shaft of the gear unit is readily accessible.
✓
The protective caps have been removed from the shaft and the propeller-end
mechanical seal.
1. Rotate the drive shaft so that key 940 points upwards.
2. Guide propeller 23-9 onto the shaft end so that the keyway in the hub aligns
with key 940.
3. Slip the propeller onto the shaft until it will not go any further.
4. Coat the thread of screw 914.06 and the face of disc 550.01 which rests against
the propeller with thread-locking agent.
5. Fit screw 914.06 and disc 550.01. (
7.6
Tightening torques
Table 13: Tightening torques
Thread
Torque
[Nm]
M5
4
M6
7
M8
17
M10
35
M12
60
M16
150
7.7
Spare parts stock
7.7.1 Recommended spare parts stock for 2 years' operation to DIN 24296
Table 14: Quantity of spare parts for recommended spare parts stock
Part No. Description
Number of mixers (including stand-by mixers)
2
3
4
5
6
8
10 and more
Type
6)
80-1
Motor unit (motor housing 811, stator 81-59)
-
-
-
1
1
2
3
E
834
Cable gland
1
1
2
2
2
3
40%
R
818
Rotor with plug-in pinion
7)
-
-
-
1
1
2
3
E
99-2
Installation kit for gear unit
8)
-
-
-
1
1
2
3
E
23-9
Propeller
1
1
1
2
2
3
30%
E
433.01
Mechanical seal, gear side
2
3
4
5
6
7
90%
V
433.02
Mechanical seal, propeller side
2
3
4
5
6
7
90%
V
321.01
Rolling element bearing, gear side
1
1
2
2
3
4
50%
R
321.02
Rolling element bearing, motor side
1
1
2
2
3
4
50%
R
322
Radial roller bearing
1
1
2
2
3
4
50%
R
Set of sealing elements
4
6
8
8
9
10
100%
V
7.7.2 Ordering spare parts
Always quote the following data when ordering replacement or spare parts:
▪
Designation of submersible mixer
▪
Motor number
Refer to the name plate for all data.
Also supply the following data:
6)
E = spare part, R = replacement part, V = wear part; it is recommended to keep a stock of wear and replacement parts
7)
From installation kit (Amaprop 1200 to 2500 only)
8)
Always in combination with rotor only (except for Amaprop 1000 with slip-on pinion; Amaprop 1200-2500: pinion pressed
in at factory)
7 Servicing/Maintenance
42 of 60
Amaprop®
Goodnal STP ST041 Biological Treatment (KSB Amaprop Installation and Operating Manual) Vendor Manual
Q-Pulse Id VM386
Active 29/10/2013
Page 42 of 60