7 Servicing/Maintenance
64 of 126
Amacan S
1589.837/01-EN
7.5.3 Removing the bellmouth
138
920.01
502
Fig. 34:
Removing the bellmouth
ü
The pump set has been disconnected from the power supply and secured against
unintentional start-up.
ü
The pump set has been placed in a vertical position with the bellmouth on
wooden supports and secured against tipping over.
1. Undo nuts 920.01.
2. Attach the crane hook to the bail and lift the pump set off bellmouth 138.
Casing wear ring 502 remains in bellmouth 138.
3. Place the pump set in a horizontal position on wooden supports and make sure
it cannot roll off.
7.5.4 Removing the impeller
914.07
922
210
940.02
230
Fig. 35:
Removing the impeller
ü
The pump has been placed in a horizontal position on wooden supports and is
protected against rolling off.
ü
The leakage has been drained.
1. Undo socket head cap screw 914.07 and impeller nut 922.
2. Pull impeller 230 off shaft 210.
3. Remove keys 940.02 from shaft 210.
4. Protect the shaft thread against damage.