KS P LINE User Manual Download Page 5

POWER LINE ARRAY  

P LINE OPERATING INSTRUCTIONS

                                                                                                   4 | 

P a g e

 

PROLOGUE 

Thank you very much for your confidence in our product line-up and purchasing professional KS 

AUDIO sound reinforcement tools ! 

Please read this manual carefully and do not hesitate contacting KS AUDIO headquarter having 
further questions depending the utilization of your product ! 

OVERVIEW 

The P Line is the latest line array product to join the KS AUDIO line array portfolio between T LINE 

and cost effective C LINE boxes. As a passive box it is powered via the KS AUDIO digitally controlled 
amplifiers. A single KS AUDIO power amplifier TA4D (4 x 1000 watts per channel) will interconnect 

four P LINE units. The KS AUDIO F MOD digital controller system is added with each power amplifier 
and features a variety of FIR Filters, cross-over alignments, high pass filters, limiters, time alignments, 
delays, DSP programs with user selectable equalization as well as factory tuned dispersion with auto 

equalization characteristic patterns. That allows the user to name the number of vertical units to 
achieve optimum splay. The P LINE mechanics are compatible to T LINE, C LINE, CWL and P WK. Each 

P LINE is equipped with 2 x 10" (1000W/8ohm) and with 2 x 1" drivers (160W/8ohm) capable of large 
signal up to 142db peak. 

QUICKSTART 

 

Note: Please check when opening the package, that there is no 
obvious damage due to shipment, which could be harmful to 
the product or the operator. 

 

P LINE will always be shipped with integrated flyware, connectors and three 8mm locking pins each. 
Please check your rigging components on completeness, integrity and mechanical fit. 
 

Caution: never use damaged equipment! 
 

For calculation of splay, directivity and system equalization, EASE FOCUS 2 data sets are available. 
Build up designated arrays and connect speaker wires to Speakon input at cabinets’ backside and 
also secure these on RIG CP. After checking all mechanical and electrical connections please hoist 
the array to right height in safety position with certified straps attached and secured. 
 
 
Now you can start activating and firing up your P LINE.  
 
 

 
 
 
 
 

Summary of Contents for P LINE

Page 1: ...MANUAL P LINE Thank you for purchasing KS AUDIO Line Array Speakers Please carefully follow the instructions in this manual to ensure long trouble free use of your equipment P LINE LINE ARRAY 2x 10 2...

Page 2: ...lifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug 10 Protect the power cord from being walked on or pinched particularly at plugs convenience recepta...

Page 3: ...NT _________________________________ 6 ADJUSTMENT WITH GEARDRIVE OPTIONAL AVAILABLE __________ 6 CONNECTIONS AND AMPLIFIERS________________________________ 7 SPECIFICATIONS____________________________...

Page 4: ...d via Powercon plug do not disconnect under all circumstances Mains always have to be equipped with protective ground Also all electronic devices connected together with signal core must use common pr...

Page 5: ...ispersion with auto equalization characteristic patterns That allows the user to name the number of vertical units to achieve optimum splay The P LINE mechanics are compatible to T LINE C LINE CWL and...

Page 6: ...l or do your calculation in EASE FOCUS 2 recommended The maximum number of P LINE Elements per cradle is 12 The array then has a total weight of 380kg plus cables Never use damaged parts Check your ma...

Page 7: ...setting can be found as controller preset within KS AUDIO amplification Just choose array length number and curving splay between two flanking line array elements and speaker set up is finished and r...

Page 8: ...damage parts of equipment KS AUDIO recommends employing balanced input connections KS recommends the use of 4 x 2 52 cable for all speaker to amplifier connections for optimal performance Warning be...

Page 9: ...th F MOD drivers 2 x 10 ND cone 2 x 1 power in Wrms 1000W 160W at 4 8 Ohms sensitivity 1W 1m 113dB driver waveguide amplification x over 2 way bi amp 1000Hz input connectors speakon NL4 output connect...

Page 10: ...lth criteria of the applicable EC respectively EU directives This declaration shall cease to be valid if alternations are made to the equipment without our prior agreement This declaration covers orde...

Page 11: ...umstances Please avoid water condensation at any electronic device under all circumstances Whenever system carried e g from cold truck to warm and humid event location always allow equipment to acclim...

Page 12: ...ys 24 month limited warranty of manufacturer to the exclusion of all further claims and the following obligations Exchange or repair of defect devices whenever not subject of external damage vandalism...

Page 13: ...POWER LINE ARRAY P LINE OPERATING INSTRUCTIONS 12 P a g e NOTES Model Serial Number Purchase Date...

Page 14: ...CONTACT KS BESCHALLUNGSTECHNIK GMBH WESTENDSTRASSE 1 D 67310 HETTENLEIDELHEIM fon 49 6351 12744 0 email info ks audio de web www ks audio de SERVICE email service ks audio de...