11
10
DELAY IN TIME: It is recommended to change the delay in time for
flush valves for urinals or toilets only.
If required, the delay in time can also be modified in faucets as
follows:
Press the IN button. wait until a quick flashing of the LED in the
sensor eye is perceived. Then, press + to increase the delay in time
and – to reduce it.
DELAY OuT TIME: This button allows modifying the water flow time
after the user removes his hands from the faucet. A delay out time
close to 0 will save more water. An increased delay out time will
make the user experience more comfortable.
If required, the delay out time can be modified as follows:
Press the OuT button. wait until a quick flashing of the LED in the
sensor eye is perceived. Then, press + to increase the delay out time
and – to reduce it.
24 HOuR HYgIENE FLuSH: This model includes a 24 hours hygiene
flush which is disabled. To activate the hygiene flush, press the clock
button. wait until a quick flashing of the LED in the sensor eye is
perceived. Then press + to activate the hygiene flush. To disable it
again, press – to deactivate it.
COMFORT FLuSH: If your model includes a Comfort flush setting, it
can be activated by pressing the flush button.
when the button is pressed, one blink of the LED in the sensor eye
is perceived. The pre-programmed flush cycle will take place then.
The Comfort flush cannot be interrupted or deactivated by pressing
any button until it is over.
TEMPORARY OFF FuNCTION: This function is ideal to perform any
kind of activity in front of the sensor without operating the system
(for example, cleaning).
The faucet will remain shut for 1 minute when this button is pressed
once. To cancel this function and to return to normal operation press
the On/Off button again or wait
1 minute.
RESET BuTTON: This function restores all the factory settings
except for the sensor range. If required, press the Reset button and
without releasing it, press the + button once.
NOTE:
To enter the self adjusting mode, use the ADJ button. To change the sensor
range, use the RANgE button.
sETTINGs ADjUsTMENT
when the battery weakens, the LED indicator will blink at a constant rate.
The battery must be replaced within two weeks.
To replace the battery in ÁLAMO / ÁLAMO DúO:
1) Turn off the shut off valve.
2) Remove the faucet cover with the sensor, use the supplied Allen key.
3) Disconnect the connector coming from the electronic unit to the battery.
4) Replace the used battery with a new 9V battery. A Lithium battery is
recommended.
5) Carefully place the battery inside the body and reassemble the electronic unit
connector to the battery.
Important:
- Since water contacting the battery terminals rapidly drains the battery,
do not allow moisture or water into the system while the battery is being
replaced.
- Make sure the O-ring is still in its groove and is not damaged. If needed
replace it with a new one or clean and lubricate it with silicon grease before
reassembling the parts.
6) You must reassemble the faucet cover with the sensor within 30 seconds
in order for the sensor self adjustment to be done properly.
BATTERY REPLACEMENT
ÁLAMO / ÁLAMO DúO