CAUTION

CLEANING & MAINTENANCE

OPERATION

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE

FOLLOWING:

1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the 

manufacturer at the address or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at service panel and lock the service discon-

necting means to prevent power from being switched on accidentally. When the service discon-

necting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the 

service panel.

3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all 

applicable codes and standards, including fire-rated construction codes and standards.

4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) 

of fuel burning  equipment to prevent backdrafting. Follow the heating equipment manufacturer’s 

guideline and safety standards such as those published by the National Fire Protection Association 

(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning  Engineers 

(ASHRAE), and the local code authorities.

5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utili-

ties.

6. Ducted fans must always be vented to the outdoors.

7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupt-

er) - protected branch circuit (ceiling installation only).

8. This unit must be grounded.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. 

DO NOT MOUNT THIS PRODUCT IN A WALL.

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off 

power unit.

4. Please read specification label on product for further information and requirements. 

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit 

with the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual 

noises, replace the motor with the exact service motor. The impeller should also be replaced.

See “CONNECT ELECTRICAL WIRING” for details.