Maintenance – General
11
Tightening torques
11.2
KWT 1600
Original Operating Instructions 150000169_04_en
69
Components
Touch up damaged paint and preserve un-
coated areas with rust protection agent
Check that all moveable components move
freely. If required, dismount, clean, grease and
remount.
Park the machine in a weatherproof and dry
location which is not in close proximity to cor-
rosive substances
Protect the tyres against external influences
such as oil, grease or direct sunlight
Move the machine every 2 months
11.1.3
Maintenance – once after 10 hours
Components
Check tyre pressure
Retightening wheel nuts
Tighten screws/nuts on the machine
Check screws on the tines
11.1.4
Maintenance – every 50 hours
Components
Check tyre pressure
Retightening wheel nuts
Tighten screws/nuts on the machine
Check screws on the tines
11.1.5
Maintenance – Every 1000 hours
Changing oil
Main gearbox
11.2
Tightening torques
Deviating tightening torques
All screw connections must in general be tightened with the listed tightening torques following.
Deviations from the tables are marked accordingly.
Metric thread screws with control thread
INFORMATION
The table does not apply to countersunk screws with hexagon socket in case the countersunk
screw is tightened via hexagon socket.